ACOUSTIC STANDARDS LABORATORY CALIBRATION / TEST LIST

ACOUSTICS & VIBRATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2AK-1100  Reciprocity Calibration of 1" Standard Reference Microphones (10 Hz - 10 kHz frekans aralığındaki 1/3 Oktav Bant Merkez Frekanslarında)   
G2AK-1200  Reciprocity Calibration of ½ " Standard Reference Microphones (Calibration at 1/3 octave band center frequencies in the range from 10 Hz to - 25 kHz)   
G2AK-1500  Comparison Calibration of Condenser Microphones and Determination of Frequency Response (Determination of absolute sensitivity at frequency of 250 Hz and frequency response by electrostatic actuator.)   
G2AK-1600  Determination of Free Field Response of Condenser Microphone by Comparision Method (Calibration at 1/3 octave band center frequencies in the frequency range 1 kHz to 16 kHz)   
G2AK-2100  Calibration of Sound Level Calibrator   
G2AK-2300  Calibration of Pistonphone within Sound Intensity Set   
G2AK-2400  Calibration of Multifunction Acoustical Calibrator   
G2AK-3100  Calibration of Sound Level Meter (Acoustical Tests) 
G2AK-3110  Calibration of Sound Level Meter (Acoustical and Electrical Tests) 
G2AK-3150  Determination of Free Field Response of Sound Level Meter (Calibration at 1/3 octave band center frequencies in the frequency range 1 kHz to 16 kHz)   
G2AK-3200  Calibration of Noise Dose Meter   
G2AK-3500  Calibration of Pure Tone Audiometer   
G2AK-3600  Calibration of Hearing Aid Analyzer   
G2AK-3700  Calibration of Artificial Ear   
G2AK-3800  Calibration of Artificial Mastoid   
G2AK-3900  Calibration of Ear Simulator   
G2AK-4300  Sound Power/Intensity Measurement  1,2,4,5 
G2AK-4310  Sound Pressure/Power Measurement in Special Acoustical Rooms  1,2,5 
G2AK-4400  Calibration of Reference Sound Source ( ISO 6926)   
G2AK-5100  Determination of Acoustical Properties of Materials  1,2,5 
G2AK-6100  Reverberation Time Measurement  2,4 
G2AK-6210  Daily Use of Full/Semi Anechoic Room / (8 Hours) 
G2AK-6220  Daily Use of Reverberation Room / (8 Hours) 
G2AK-7100  Calibration of Microphone Preamplifier (Calibration at 1/3 octave band center frequencies in the frequency range 20 Hz to 25 kHz)   
G2AK-7200  Calibration of Signal Contioner (Calibration at 1/3 octave band center frequencies in the frequency range 20 Hz to 25 kHz)   
G2AK-9900  Special Calibration / Test  2,4,5 
(1) Accredited Service 
(2) Cost of the service is determined based on your request. 
(3) Equipment belongs to the customer is used for this service 
(4) Accommodation and transportation costs will be added to the measurement cost 
(5)  
(6)  



VIBRATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2TI-1100  Absolute Calibration of Standard Reference Accelerometers by Laser Interferometry ( (Calibration at 1/3 octave band center frequencies in the frequency range 10 Hz to 10 kHz) 
G2TI-1500  Comparison Calibration of Accelerometers (at 160 Hz) and Determination of Frequency Response  2,6 
G2TI-1800  Absolute Calibration of Shock Transducers by Laser Interferometry 
G2TI-1900  Comparison Calibration of Shock Transducers 
G2TI-2100  Calibration of Vibration Exciter (Calibration at each frequency other than 159.15 Hz is performed at additional cost of 440 TL).   
G2TI-2200  Calibration of Vibration Measuring Set Calibration performed at the frequency of 160 Hz. Calibration at each frequency other than 160 Hz is performed at additional cost of 550 TL 
G2TI-3100  Calibration of Impact Hammer   
G2TI-4100  Measurement of Mechanical Vibrations (Total Amplitude) (up to 10 measurement points)  3,4 
G2TI-4200  Frequency Analysis of Mechanical Vibrations (up to 10 measurement points)  3,4 
G2TI-5100  Measurement of Gravity Acceleration  5, 7 
G2TI-6100  Calibration of Conditioning Amplifier 
G2TI-7100  Calibration of Impedance Head (Calibration at 1/3 octave band center frequencies in the frequency range 100 Hz to 8 kHz)   
G2TI-9900  Special Calibration / Test  3,4,5 
(1) Calibration at each frequency other than 160 Hz is performed at additional cost of 125 TL 
(2) Calibration cost for triaxial accelerometers and vibration meters with triaxial accelerometer is two times of the single axis calibration price. 
(3) Acredited Service for hand-arm vibration measurement. 
(4) Cost of the service is determined based on your request. 
(5) Accomodation and trasportation costs are added to the measurement cost 
(6)  
(7)  
(8)