TÜBİTAK UME CALIBRATION / TEST LIST

ACOUSTICS & VIBRATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2AK-1100  Reciprocity Calibration of 1" Standard Reference Microphones (10 Hz - 10 kHz frekans aralığındaki 1/3 Oktav Bant Merkez Frekanslarında)   
G2AK-1200  Reciprocity Calibration of ½ " Standard Reference Microphones (Calibration at 1/3 octave band center frequencies in the range from 10 Hz to - 25 kHz)   
G2AK-1500  Comparison Calibration of Condenser Microphones and Determination of Frequency Response (Determination of absolute sensitivity at frequency of 250 Hz and frequency response by electrostatic actuator.)   
G2AK-1600  Determination of Free Field Response of Condenser Microphone by Comparision Method (Calibration at 1/3 octave band center frequencies in the frequency range 1 kHz to 16 kHz)   
G2AK-2100  Calibration of Sound Level Calibrator   
G2AK-2300  Calibration of Pistonphone within Sound Intensity Set   
G2AK-2400  Calibration of Multifunction Acoustical Calibrator   
G2AK-3100  Calibration of Sound Level Meter (Acoustical Tests) 
G2AK-3110  Calibration of Sound Level Meter (Acoustical and Electrical Tests) 
G2AK-3150  Determination of Free Field Response of Sound Level Meter (Calibration at 1/3 octave band center frequencies in the frequency range 1 kHz to 16 kHz)   
G2AK-3200  Calibration of Noise Dose Meter   
G2AK-3500  Calibration of Pure Tone Audiometer   
G2AK-3600  Calibration of Hearing Aid Analyzer   
G2AK-3700  Calibration of Artificial Ear   
G2AK-3800  Calibration of Artificial Mastoid   
G2AK-3900  Calibration of Ear Simulator   
G2AK-4300  Sound Power/Intensity Measurement  1,2,4,5 
G2AK-4310  Sound Pressure/Power Measurement in Special Acoustical Rooms  1,2,5 
G2AK-4400  Calibration of Reference Sound Source ( ISO 6926)   
G2AK-5100  Determination of Acoustical Properties of Materials  1,2,5 
G2AK-6100  Reverberation Time Measurement  2,4 
G2AK-6210  Daily Use of Full/Semi Anechoic Room / (8 Hours) 
G2AK-6220  Daily Use of Reverberation Room / (8 Hours) 
G2AK-7100  Calibration of Microphone Preamplifier (Calibration at 1/3 octave band center frequencies in the frequency range 20 Hz to 25 kHz)   
G2AK-7200  Calibration of Signal Contioner (Calibration at 1/3 octave band center frequencies in the frequency range 20 Hz to 25 kHz)   
G2AK-9900  Special Calibration / Test  2,4,5 
(1) Accredited Service 
(2) Cost of the service is determined based on your request. 
(3) Equipment belongs to the customer is used for this service 
(4) Accommodation and transportation costs will be added to the measurement cost 
(5)  
(6)  



AIR VELOCITY MEASUREMENTS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2AH-0900  Micro Anemometer 0.5-40 m/s Anemometer Calibrations by Static Pitot Tube  1,2,3,5 
G2AH-9900  Specific Anemometer Measurements  4,5 
(1) Acredited item. 
(2)  
(3)  
(4) Price depends on type of test and type of device. 
(5)  



ANGLE MEASUREMENTS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2BC-1100  Autocollimator  1, 3 
G2BC-1200  Electronic Level (per couple) 
G2BC-1600  Clinometer 
G2BC-2100  Angular Gauge Blocks (per piece)  1, 2, 3 
G2BC-2200  True Square 
G2BC-2300  Optical Polygon (price for each measuring surface) 
G2BC-2500  Index Table (with 30° increments)  1, 4 
G2BC-3000  Adjustable Reference Mirror with one face 
G2BC-3100  Adjustable Reference Mirror with double face 
G2BC-3200  Magnetic Back Mirror 
G2BC-3300  Rotary Table  1, 3 
G2BC-3400  Small Angle Generator   
G2BC-9900  Special Calibration / Test 
(1) Accredited Item. 
(2) Valid for 90° Angle gauge blocks in form of True Square 
(3) Price quoted will be determined acc. to request. Prices differ depending on the service. Given price is the lowest calibration price 
(4)  
()  



BIOANALYSIS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G3BA-1100   
G3BA-1110  Relative quantification of GMO DNA (MON810) in seeds - Real Time PCR Instrument 
G3BA-1120  Relative quantification of GMO DNA (Bt63) in seeds - Real Time PCR Instrument 
G3BA-1210  Relative quantification of GMO DNA (MON810) in seeds - Digital PCR Instrument 
G3BA-1220  Relative quantification of GMO DNA (Bt63) in seeds - Digital PCR Instrument 
G3BA-1230  Relative quantification of GMO DNA (DP-Ø73496-4/RT73) in seeds - Digital PCR Instrument 
G3BA-1310  Meat Authentication, Qualitative Analysis (Beef) - Digital PCR Instrument 
G3BA-1320  Meat Authentication, Qualitative Analysis (Pork) - Digital PCR Instrument 
G3BA-1330  Meat Authentication, Qualitative Analysis (Horse) - Digital PCR Instrument 
G3BA-1340  Meat Authentication, Qualitative Analysis (Camel) - Digital PCR Instrument 
G3BA-1350  Meat Authentication, Qualitative Analysis (Sheep) - Digital PCR Instrument 
G3BA-1360  Meat Authentication, Qualitative Analysis (Goat) - Digital PCR Instrument   
G3BA-1370  Meat Authentication, Qualitative Analysis (Chicken) - Digital PCR Instrument   
G3BA-1380  Meat Authentication, Qualitative Analysis (Duck) - Digital PCR Instrument 
G3BA-1390  Meat Authentication, Qualitative Analysis (Salmon) - Digital PCR Instrument 
G3BA-1410  Meat Authentication, Quanitative Analysis (Beef) - Digital PCR Instrument 
G3BA-1420  Meat Authentication, Quantitative Analysis (Pork) - Digital PCR Instrument   
G3BA-1430  Meat Authentication, Quantitative Analysis (Horse) - Digital PCR Instrument 
G3BA-1440  Meat Authentication, Quantitative Analysis (Camel) - Digital PCR Instrument 
G3BA-1450  Meat Authentication, Quantitative Analysis (Sheep) - Digital PCR Instrument 
G3BA-1460  Meat Authentication, Quantitative Analysis (Goat) - Digital PCR Instrument 
G3BA-1470  Meat Authentication, Quantitative Analysis (Chicken) - Digital PCR Instrument 
G3BA-1480  Meat Authentication, Quantitative Analysis (Duck) - Digital PCR Instrument 
G3BA-1490  Meat Authentication, Quantitative Analysis (Salmon) - Digital PCR Instrument 
G3BA-1610   
G3BA-1620   
G3BA-1630   
G3BA-1640   
G3BA-2100  Relative quantification of RNA transcripts - Real Time PCR Instrument  1, 3 
G3BA-3100  Relative quantification of DNA methylation levels - Real Time PCR Instrument Melting Analysis  1, 3 
G3BA-3200    1, 3 
G3BA-4100  Absolute quantification of plasmid DNA - Digital PCR Instrument  1, 3 
G3BA-4210  Relative quantification of oncogenes (KRAS-G12D) - Digital PCR Instrument  1, 4 
G3BA-4220  Relative quantification of oncogenes (BRAF-V600E) - Digital PCR Instrument  1,4 
G3BA-4230  Relative quantification of oncogenes (EGFR-?746-750) - Digital PCR Instrument  1, 4 
G3BA-4310  Absolute quantification of HIV virus - Digital PCR Instrument  1, 4 
G3BA-4320  Absolute quantification of SARS-CoV-2 virus - Digital PCR Instrument  1,3,4 
G3BA-5100  Amino acid analysis for pure protein/peptide - LC-ID-MS 
G3BA-5300  Quantification of C-peptide/angiotensin - LC-ID-MS(n) 
G3BA-5400  Quantification of protein concentration - HPLC 
G3BA-5500  Quantification of protein concentration - ELISA 
G3BA-5600  Quantification of protein/peptide concentration - PICAA Analysis 
G3BA-5700  Relative quantification of HbA1c protein - HPLC 
G3BA-5800  Relative quantification of HbA1c protein - LC-ID-MS 
G3BA-5900  Determination of amylase enzyme activity - Spectrophotometric 
G3BA-6000  Complex Proteome Analysis - Relative Quantification (LFQ-TMT) 
G3BA-6100  Identification of Post Translational Modifications ( Methylation, Acetylation, Phosphorylation etc.) 
G3BA-6200  Peptide Fragmentation (HCD) 
G3BA-6300  LC-MS/MS Method based protein identification 
G3BA-9900  Special Calibration / Test 
(1) Pricing is for one sample, please inquire pricing for more than two samples 
(2) Price depends on the requirements. 
(3)  
(4)  



CAPACITANCE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1KA-1100  Standard Capacitance Calibration (1 kHz)  1, 2 
G1KA-1150   
G1KA-1200  Standard Capacitance Calibration (50 Hz - 20 kHz) (for 5 frequency point)  1, 2 
G1KA-1300  Standard Capacitance Calibration (1 kHz – 30 MHz) (for 15 frequency point)  1, 2 
G1KA-1400  Capacitance Bridge Calibration 
G1KA-1600  Calibration of multifunction calibrator (capacitance part ) 
G1KA-1700     
G1KA-2100  Standard Inductance Calibration  1, 4 
G1KA-3100  AC Resistance Calibration  1, 2 
G1KA-3300  Impedance Calibration (Frequency < 110 MHz)  5, 6 
G1KA-3310    5, 6, 7 
G1KA-4200  RLC Meter Calibration 
G1KA-5100  AC1 Artificial Cable Calibration 
G1KA-5500  Cable Test Devices Calibration   
G1KA-5700  AC Null Dedector Calibration   
G1KA-6300  IVD Calibration (1 kHz)  1, 8 
G1KA-7000  Strain Gauge Indicator Calibration (For each channel)   
G1KA-9900  Special Calibration / Test 
(1) Accredited Item. 
(2) If more frequency points are requested, 330 TL is added for each extra frequency point to the price. 
(3) Price depends on the requirements. 
(4)  
(5)  
(6)  
(7)  
(8)  



CONTACT THERMOMETRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1KS-0100  Comparisons of Fixed Point Cells  1, 2, 4 
G1KS-0110  Comparison of Argon Cell  1, 2, 4 
G1KS-0120  Comparison of Mercury Cell  1, 2, 4 
G1KS-0130  Comparison of Gallium Cell  1, 2, 4 
G1KS-0140  Comparison of Indium Cell  1, 2, 4 
G1KS-0150  Comparison of Tin Cell  1, 2, 4 
G1KS-0160  Comparison of Zinc Cell  1, 2, 4 
G1KS-0170  Comparison of Aluminum Cell  1, 2, 4 
G1KS-0180  Comparison of Silver Cell  1, 2, 4 
G1KS-0200  -189.3442 °C / +29.7646 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0210  -189.3442 °C / +156.5985 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0220  -189.3442 °C / +231.928 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0230  -189.3442 °C / +419.527 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0240  -189.3442 °C / +660.323 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0250  -38.8344 °C / +29.7646 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0260  -38.8344 °C / +156.5985 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0270  -38.8344 °C / +231.928 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0280  -38.8344 °C / +419.527 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0290  -38.8344 °C / +660.323 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0300  0.01 °C / +156.5985 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0310  0.01 °C / +231.928 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0320  0.01 °C / +419.527 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0330  0.01 °C / +660.323 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0340  0.01 °C / +961.78 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0350  0.01 °C / +29.7646 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 5 
G1KS-0370  0.01 °C / 1084 °C Resistance Thermometer (SPRT, HTPRT) Calibration at Fixed Point Defined by ITS 90  1, 2, 4, 8 
G1KS-0380  419.527 °C / 1324 °C   
G1KS-0490  -196 °C / 0 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 6 
G1KS-0495  -80 °C / 0 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 6 
G1KS-0500  -80 °C / +85 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 6 
G1KS-0510  -80 °C / +250 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 8 
G1KS-0520  -80 °C / +550 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 9 
G1KS-0530  0 °C / +85 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 6 
G1KS-0540  0 °C / +250 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 8 
G1KS-0550  0 °C / +550 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 8 
G1KS-0560  -80 °C / +650 °C  1, 2, 4, 9 
G1KS-0570  -196 °C / +550 °C Calibration of Resistance/ Digital Thermometer (Pt-100, Intelligent Prob, thermistor etc) by comparison method  1, 2, 4, 9 
G1KS-0580    1, 2, 4, 9 
G1KS-0850  600 °C/ 1100 °C Calibration of Thermocouples and Digital Thermometers by Comparison Method  1, 2, 3, 4, 6 
G1KS-0870  600 °C / 1300 °C Calibration of Thermocouples and Digital Thermometers by Comparison Method  1, 2, 3, 4, 6 
G1KS-0890     
G1KS-0910  Calibration of Temperature-Controlled Volumes for one temperature calibration points 
G1KS-0915   
G1KS-0920  -40 °C / 420 °C  1, 6 
G1KS-0930    1, 6 
G1KS-9900  Special Calibration / Test  2, 5 
G1KS-9910     
(1) Acredited Calibration. 
(2) Please specify the calibration temperature range, thermometer diameter, immersion depth in the calibration request form and send all relevant documents (manuals, certificates etc) 
(3) As a calibration acceptance criteria; the maximum diameter of the platinum based thermocouples should be 7 mm and its protection tube should be of very clean ceramic material. 
(4) Please note that laboratory will not be held responsible for any damages occurring to the equipment during the calibration process and up to 50% of calibration price will be demanded in case the instrument under calibration malfunctions or shows instability. 
(5)  
(6) Calibration price is determined for up to five calibration points. Additional points will subject to extra price. 
(7) Calibration points that should lie within -80 °C and 200 °C should be specified by the customer. 
(8) Calibration price is determined for up to seven calibration points. Additional points will subject to extra price. 
(9)  



DC VOLTAGE CALIBRATION / TEST LIST

CODE NAME NOTE
G1LR-1100  Standard Resistance Calibration (0,1 m Ohm <= R <= 100 mOhm) (Only for one current)  1, 2 
G1LR-1300  Standard Resistance Calibration (100 mOhm < R<=10 kOhm ) (Only for one current)  1, 2 
G1LR-1500  Standard Resistance Calibration (10 kOhm < R <= 1 GOhm ) (Only for one voltage)  1, 2, 5 
G1LR-1700  Standard Resistance Calibration (1 GOhm < R 1 TOhm ) (Only for one voltage)  1, 2 
G1LR-2300  DC Current Shunt Calibration (0-100 A) (Only for one current)  1,2 
G1LR-2500  DC Current Shunt Calibration 9211A (0-100 A)  1,6 
G1LR-4000  Precision Resistance Meter 
G1LR-4700  Ohmmeter Calibration  1, 3 
G1LR-5100  Temperature Coefficient Calculation of Standard Resistances (1 Ohm - 10 kOhm , Temperature Range 20 °C – 25 °C) 
G1LR-7100  Surface and Volume Resistivity Measurement   
G1LR-7200  Surface Resistivity Measurement   
G1LR-7300  Volume Resistivity Measurement   
G1LR-7600  Contact Resistance Experiment   
G1LR-7700  Isolation Resistance Experiment   
G1LR-8100  AC Conductivity Measurement Device Calibration  1, 3 
G1LR-8200  AC Conductivity Standard Calibration ( For each standard) 
G1LR-9100  Low Current Measuring Device Calibration (2 pA – 10 µA)  1, 3 
G1LR-9200  Low Current Source Calibration (2 pA – 10 µA)  1, 3 
G1LR-9900  Special Calibration / Test 
(1) Accredited Item. 
(2) The half of the calibration price is added to the calibration price for each extra measurement point. 
(3) If your instrument works on batteries please provide spare batteries. Please specify explicitly if your instrument works with power supply other than 220 VAC. 
(4) Price depends on the requirements. 
(5) Maximum measurement voltage is 100 V. 
(6) The half of the calibration price of G1LR-2300 is added to the calibration price for each extra current. 



ELECTROCHEMISTRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G3EK-1401  Determination of pH 4 CRM by Primary Level pH Measurement System 
G3EK-1402  Determination of pH 7 CRM by Primary Level pH Measurement System 
G3EK-1403  Determination of pH 10 CRM by Primary Level pH Measurement System 
G3EK-1404  Determination of Conductivity by Primary Level Conductivity Measurement System 
G3EK-1450  Cyclic Voltammetric (CV) Measurements 
G3EK-9900  Special Calibration / Test 
(1) Price depends on the requirements 



ELECTROMAGNETIC RADIATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1ER-0100  It is called "electrical bursts (electrical fast transients)" in type tests.   1, 2, 19, 21 
G1ER-0200  Conducted Emission (Use of Absorbing Clamp)  1, 2, 19, 21 
G1ER-0300  Conducted Emission (Use of DIA)  1, 2, 19, 21 
G1ER-0400  Conducted Emission (Use of Current Probe)  1, 2, 19, 21 
G1ER-0500  Conducted Emission (Use of Voltage Probe)  1, 2, 19, 21 
G1ER-0600  Conducted Emission (Harmonics)  1, 2, 19, 21 
G1ER-0700  Conducted Emission (Flicker)  1, 2, 19, 21 
G1ER-0800  Radiated Emission  1, 2, 19, 21 
G1ER-0900  Conducted Immunity (Use of CDN)  1, 2, 19, 21 
G1ER-0950  Conducted Immunity (Use of BCI)  1, 2, 19, 21 
G1ER-1000  Conducted Immunity (ESD)  1, 4, 14, 19, 21 
G1ER-1100  Conducted Immunity (EFT)  1, 2, 15, 19, 21 
G1ER-1200  Conducted Immunity (Surge)  1, 2, 18, 19, 21 
G1ER-1300  Conducted Immunity (Voltage Dips and Interruptions)  1, 2, 16, 19, 21 
G1ER-1350  Magnetic Immunity (50 / 60 Hz)  1, 2, 19, 21 
G1ER-1400  Radiated Immunity (3 V/m - 30 V/m, 26 MHz - 6.5 GHz)  1, 3, 17, 19, 21 
G1ER-3230  Full EMC Tests of Vehicles and Tractors According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive  1, 3, 19, 21 
G1ER-3330  EMC Tests of Vehicle/Tractor Sub-Assemblies According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive   1, 3, 19, 21 
G1ER-3600  RE101, Magnetic Field, 30 Hz - 100 kHz  1, 2, 4, 19, 21 
G1ER-3700  RE102, Electric Field (10 kHz –- 18 GHz)  1, 3, 4, 19, 21 
G1ER-3900  CE101, Power Leads, 30 Hz - 10 kHz (single phase)  1, 2, 19, 21 
G1ER-4000  CE102, Power Leads, 10 kHz - 10 MHz (single phase)  1, 2, 19, 21 
G1ER-4200  RS101, Magnetic Field, 30 Hz - 100 kHz  1, 2, 4, 6, 11,19, 21 
G1ER-4300  RS103, Electric Field, 2 MHz - 18 GHz, 10 V/m - 200 V/m, EUT Surface up to 900 cm²   1, 3, 5, 6, 7, 10, 19, 21 
G1ER-4400  CS101, Power Leads, 30 Hz - 150 kHz (single phase)  1, 2, 6, 11, 19, 21 
G1ER-4710  CS106 Power Leads, (single phase)  1, 2, 11, 19, 21 
G1ER-4900  CS114, Bulk Cable Injection, 10 kHz - 200 MHz  1, 2, 6, 11, 19, 21 
G1ER-5000  CS115, Bulk Cable Injection/Impulse Excitation  1, 2, 11, 19, 21 
G1ER-5100  CS116, Damped Sinusoidal Transients  1, 2, 11, 19, 21 
G1ER-5110  CS118, Electrostatic Discharge  1, 4, 19, 21 
G1ER-5210  Active-Passive Rod and Loop Antenna Calibration (Frequency range: 5 Hz - 30 MHz)  8, 12, 20 
G1ER-5220  Biconical, Bilog, Log-Periodic, Horn Antenna Calibration (Frequency range: 30 MHz - 300 MHz or 200 MHz - 1 GHz)  8, 12, 13, 20 
G1ER-5225  Bilog / Mini Biconical Antenna Calibration (Frequency range: 30 MHz - 1 GHz)   8, 12, 13, 20 
G1ER-5230  Horn Antenna Calibration (Frequency range: 1 GHz - 18 GHz)  8, 12, 13, 20 
G1ER-5240  Horn Antenna Calibration (Frequency range: 18 GHz - 26,5 GHz)  8, 12, 13, 20 
G1ER-5250  Horn Antenna Calibration (Frequency range: 26 GHz - 40 GHz)  8,12,13,20 
G1ER-5310  Electric/Magnetic Field Probe Calibration ( Frequency range: 30 Hz - 32 kHz)  8, 12, 20 
G1ER-5320  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 MHz)  8, 12, 20 
G1ER-5330  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 30 MHz)  8, 12, 20 
G1ER-5340  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 GHz)  8, 12, 20 
G1ER-5350  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 20 GHz)  8, 12, 20 
G1ER-5360  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 40 GHz)  8, 12, 20 
G1ER-6100  Daily Use of Semi Anechoic Chamber (Radiated Immunity / 8 Hours)  22 
G1ER-6200  Daily Use of Semi Anechoic Chamber (Radiated Emission / 8 Hours)  22 
G1ER-6300  Daily Use of Screened Room (Conducted Emission-Immunity / 8 Hours)  22 
G1ER-6400  Absorbing Clamp Calibration  8, 20 
G1ER-6510  Voltage/Current Probe Calibration (Frequency range for voltage probes: 150 kHz - 30 MHz, Frequency range for current probes: 30 Hz - 500 MHz, measuring range (-30 dBs) - (70 dBs))  8, 20 
G1ER-9900  Special Calibration / Test 
(1) Accredited Service  
(2) 30% of the test fee will be added to the total test fee for each additional operating mode and/or each additional port/phase.  
(3) 50% of the test fee will be added to the total test fee for each additional operating mode.  
(4) 10% of the test fee will be added to the total test fee for each additional application point.  
(5) 30% of the test fee will be added to the total test fee for each additional 900 cm2 area of the EUT surface.  
(6) The stated fee is valid for a dwell time up of 6 s maximum. %50 of the test fee will be added to the total test fee for each additional time period of 6 s.  
(7) 50% of the test fee will be added to the total test fee for the frequency range of 18 GHz –- 40 GHz.  
(8) 50% of the calibration fee will be charged if the equipment under calibration is found to be defective.  
(9) The test/calibration fee is determined in accordance with the tests/calibrations to be performed.  
(10) If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Semi Anechoic Chamber (Radiated Immunity)  
(11) If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Screened Room (Conducted Emission-Immunity)  
(12) The calibration frequency range is determined as per manufacturer specifications.  
(13) Horn antenna measurements will be performed in the vertical polarization. The other antenna measurements will be performed in the horizontal polarization.  
(14) It is called "electrostatic discharges" in type tests.  
(15) It is called "electrical bursts (electrical fast transients)" in type tests.  
(16) It is called "voltage variations, short time power reductions, voltage dips and short interruptions" in type tests.  
(17) It is called "radiated immunity or immunity to radiated electromagnetic fields" in type tests.  
(18) It is called "surges" in type tests.  
(19) If you accept our offer, 15% of the total test fee must be paid in advance within 5 business days in order to reserve the specified dates for you. In order to provide the requested service, the remaining balance must be deposited in advance and the payment receipt must be sent to our institute at least 5 days before the service date. For tests cancelled up to 30 days before the service date, 15% of the previously paid amount will not be refunded and it will be invoiced and the remaining balance will be returned to you, if any. If the requested services are not cancelled in writing until 30 days in advance, 25% of the total test fee will be invoiced. If the customer does not come for testing on the specified date and postpone the tests, the daily room usage fee for radiated emission tests in our Industrial Services Catalogue will apply.  
(20) The calibration fee is valid for TÜBİTAK UME's standard calibration frequencies. Additional measurement frequencies, if requested, may be charged separately.  
(21)  
(22)  



FIBER OPTICS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1FO-8100  Fiber Optic Power (Power Meter), (1310 nm and 1550 nm) 
G1FO-8200  Fiber Optic Attenuator, (1310 nm and 1550 nm) 
G1FO-8500  OTDR (Distance and Attenuation Axes), (1310 nm and 1550 nm) 
G1FO-9900  Special Calibration / Test 
(1) For single mode FC/PC connector 
(2) The price will be evaluated with respect to the measurement conditions or customer request. 



FORCE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2KV-1100  Up to 10 kN / Tension Type Force Transducers  1,2 
G2KV-1300  Up to 100 kN / Tension Type Force Transducers  1,2 
G2KV-1500  Up to 3 MN / Tension Type Force Transducers  1,2 
G2KV-2100  Up to 10 kN / Compression Type Force Transducers  1,2 
G2KV-2300  Up to 100 kN / Compression Type Force Transducers  1,2 
G2KV-2500  Up to 3 MN / Compression Type Force Transducers  1,2 
G2KV-3100  Up to 10 kN / Tension and Compression Type Force Transducers  1,2 
G2KV-3300  Up to 100 kN / Tension and Compression Type Force Transducers  1,2 
G2KV-3500  Up to 3 MN / Tension and Compression Type Force Transducers  1,2 
G2KV-4100  Hand Type Force Measuring Devices (Force Gages)  1, 2 
G2KV-4200  Dynamic Calibration of Force Measuring Devices  2, 5 
G2KV-4300  Calibration of 4-Channel Force Measuring Devices  1,2,4 
G2KV-9900  Special Calibration / Test 
(1) The service is in the acrreditation scope. 
(2) The calibration of the force transducer is performed at 10% to 100% of the device capacity. Measurements outside this range will be charged extra. 
(3) The customer will be responsible for travel and accommodation costs for on-site services. 
(4) Includes additional measurements according to EN 12390-4. 
(5)  



GAS FLOW LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2AG-3100  0 - G4 (0 - 6 m3/h ) Gas Flowmeters  1,2,5 
G2AG-3200  Sonic Nozzles (0 - 10 m3/h) 
G2AG-3300  G4 - G40 (upto 65 m3/h) Gas Flowmeters  1,2,5 
G2AG-3900  G1000 - G1600 (upto 2500 m3/h) Gas Flowmeters  1,2,5 
G2AG-4300  G4000 – G10000 Gas Flowmeters  1,2,5 
G2AG-4700  On-site calibrations  2,3,5 
G2AG-4800  Gas Flowmeters Verfcation Tests (for 3 flowrates)  4,5 
G2AG-5000  Tests Explained in Gas Flowmeter Type Approval Regulations  4,5 
G2AG-5200  Vane Tests  4,5 
G2AG-5400  Tests for Gas Armatures  4,5 
G2AG-5600  Aspirator / Ventilator Tests  4,5 
G2AG-9900  Specific Gas Flow Calibration / Tests  4,5 
(1) Acredited item. 
(2) Calibration price changes by %50 if more then one meter output calibration is requested, if it is decided that device sent for calibration is not working properly, %50 of the normal price is requested, and if the device is not clean enough for calibration, %50 of the price will also be requsted for cleaning purposes from the customer. 
(3) On-Site calibration price is twice the price of calibration at UME and it may increase if there is any by other needs for calibration on-site. Travelling expenses will be added to the price. 
(4) Price may change according to device type and tests. 
(5)  



GAS METROLOGY LABORATORIES CALIBRATION / TEST LIST

CODE NAME NOTE
G3GA-1100  Determination of Carbondioxide in Nitrogen (Range: 1-20 % CO2 in N2  
G3GA-1101  Determination of Carbondioxide in Nitrogen (Range: 0.1-1 % CO2 in N2  
G3GA-1102  Determination of Carbondioxide in Nitrogen (Range: 100-1000 ppm CO2  
G3GA-1103  Determination of Carbondioxide in Nitrogen (Range: 10-100 ppm CO2  
G3GA-1110  Determination of Carbondioxide in Air (Range: 1-20 % CO2  
G3GA-1111  Determination of Carbondioxide in Air (Range: 0.1-1 % CO2  
G3GA-1112  Determination of Carbondioxide in Air (Range: 100-1000 ppm CO2  
G3GA-1113  Determination of Carbondioxide in Air (Range: 10-100 ppm CO2  
G3GA-1200  Determination of Carbonmonoxide in Nitrogen (Range: 0.1-10 % ppm CO)   
G3GA-1201  Determination of Carbonmonoxide in Nitrogen (Range: 100-1000 ppm CO)   
G3GA-1202  Determination of Carbonmonoxide in Nitrogen (Range: 10-100 ppm CO)   
G3GA-1203  Determination of Carbonmonoxide in Nitrogen (Range: 1-10 ppm CO)   
G3GA-1204  Determination of Carbonmonoxide in Nitrogen (Range: 0.05-1 ppm CO)   
G3GA-1210  Determination of Carbonmonoxide in Air (Range: 0.1-10 % CO)   
G3GA-1211  Determination of Carbonmonoxide in Air (Range: 100-1000 ppm CO)   
G3GA-1212  Determination of Carbonmonoxide in Air (Range: 10-100 ppm CO)   
G3GA-1213  Determination of Carbonmonoxide in Air (Range: 1-10 ppm CO)   
G3GA-1214  Determination of Carbonmonoxide in Air (Range: 0.05-1 ppm CO)   
G3GA-1300  Determination of Methane in Nitrogen (Range: 0.1-1 % CH4 in N2  
G3GA-1310  Determination of Methane in Air (Range: 0.05-5 % CH4)   
G3GA-1400  Determination of Propane in Nitrogen (Range: 0.1-1 % C3H8  
G3GA-1401  Determination of Propane in Nitrogen (Range: 10-1000 ppm C3H8)   
G3GA-1402  Determination of Propane in Nitrogen (Range: 2-10 ppm C3H8)   
G3GA-1410  Determination of Propane in Air (Range: 0.1-5 % C3H8)   
G3GA-1411  Determination of Propane in Air (Range: 10-1000 ppm C3H8)   
G3GA-1412  Determination of Propane in Air (Range: 2-10 ppm C3H8)   
G3GA-1500  Determination of Oxygen in Nitrogen   
G3GA-1600  Determination of Nitrogenmonoxide in Nitrogen   
G3GA-1700  Determination of Sulfurdioxide in Nitrogen   
G3GA-1800  Determination of Nitrogendioxide in Nitrogen   
G3GA-1900     
G3GA-4100  Automotive Exhaust Gas Analyses   
G3GA-5100  Natural Gas Analyses 
G3GA-5200  Biogas Analyses 
G3GA-5300     
G3GA-9101  ?13C-CO2 Isotope Ratio Measurements in Gases   
G3GA-9102  ?18O-CO2 Isotope Ratio Measurements in Gases   
G3GA-9800  Determination of Calorific Values of Solid Materials   
G3GA-9801  Determination of Calorific Values of Liquid Materials   
G3GA-9802  Determination of Calorific Values of Gas Materials   
G3GA-9900  Special Calibration / Test 
(1) Price depends on the requirements. 
(2) Components and range (%):
Hydrogen: 0.1-10.0
Helium: 0.05-0.5
Nitrogen: 0.1-19.9
Carbondioxide: 0.02-45.0
Ethane: 0.02-11.0
Propane: 0.005-4.0
i-butane: 0.03-0.7
n-butane: 0.03-0.7
neo-pentane: 0.01-0.05
i-pentane: 0.02-0.7
n-pentane: 0.02-0.7
n-hexane: 0.01-0.3 Methane (balance): 42.0-99.0 
(3) Components and range (%):
Nitrogen: 4 - 25
Carbondioxide: 10 - 45
Hydrogen: 0.2 - 5
Oxygen: 0.1 - 3
Ethane: 0.01 - 0.20
Propane: 0.001 - 0.20
Methane (balance): 30 - 80 
()  



GAUGE BLOCKS AND INTERFERENTIAL LENGTH MEASUREMENTS CALIBRATION / TEST LIST

CODE NAME NOTE
G2BM-1100  Short Gauge Blocks: Grade 00, K Rectangular or Square Shape (measurement by interferometry)  1,2 
G2BM-1300  Short Gauge Blocks: Grade K,0,1,2 Rectangular or Square Shape (measurement by comparison)  1,2 
G2BM-1600  Long Gauge Blocks: Rectangular or Square Shape (length between 125-1000 mm)(measurement by comparison or measurement by mechanical probing)  1,2 
G2BM-1800  Special Gauge Sets for Calibration of Mechanical Comparator 
G2BM-4000  Optical Flat (Prices differ acc.to dimensions)  1,2,3 
G2BM-4100  Optical Parallel  1,2 
G2BM-4200  Optical Flat (with 3-Flat Method by interferometry)  1,2 
G2BM-4300  Mirror / Platen / Optical Surface Flatness Measurements (Max. Diameter 150 mm)  1,2 
G2BM-4400  PZT- Nanosensor 
G2BM-9100  Angular Interferometer and Angle Reflector  1, 3 
G2BM-9200  Penta Prism (Optical Square) 
G2BM-9300  Corner Cube (Retro Reflector) 
G2BM-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) Prices are given per piece 
(3) Price of optic flat diameter ; d < 100 mm is 550 TL+KDV, 100 mm < d < 150mm is 1210 TL+KDV and d > 150 mm is 2300 TL+KDV. 



GEOMETRICAL STANDARTS AND FORM MEASUREMENTS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2BF-0100  Roundness Standards  1, 3, 4 
G2BF-0110  Magnification Standard (Flick) 
G2BF-0200  Reference Ring-Plug Gauge, Spherical Standard (for CMM) (for Set-up purposes), calibration with length measuring machine (price per piece) 
G2BF-0210  Spherical Standard for Optical Projectors (calibration with length measuring machine) 
G2BF-0300  Plain Go-NoGo Ring-Plug Gauge (calibration with length measuring machine) 
G2BF-0400  Parallel Thread Ring-Plug Gauge (calibration with length measuring machine) 
G2BF-0410  Thread Measuring Probes (double sided spherical probe)  1,3 
G2BF-0500  Thread Measuring Pins (3 pieces) 
G2BF-0510  Gear Measuring Pins (2 pieces) 
G2BF-0520  Pin Gauge (1 pieces) 
G2BF-1200  Electronic Displacement Transducers (1-D Displacement Transducers, actuators) 
G2BF-1210  Electronic Displacement Transducers (1-D Displacements Transducers, actuators) (calibration with Nano sensor, ± 7µm range) 
G2BF-1510  Dial-Indicator Tester (Resolution #?## 0.1micrometer)  1, 3 
G2BF-2000  Steel Tape (surveyor levelling rod, engineer tape, engineer scale, PI tape, geodetic wire) and Steel Rule (Up to 10m for 10 measurement points)  1,2 
G2BF-2020  Precision Line Scale (Glass Rule for Microscope and optical projectors) calibration with Optical Projector for 10 measurement points  1,2 
G2BF-2021  Precision Line Scale (Glass Rule for Microscope and optical projectors) calibration with optical projector equipped with laser Interferometer for10 measurement points  1,2 
G2BF-2030  Stage Micrometer (calibration with Mask Measuring Machine equipped with Differential Interferometer for10 measurement points.)  1,2 
G2BF-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) When measurements with more than 10 points are requested, 35 TL for each measuring point must be added to the price. The price is for the measurements of one face and one side of one scale on the ruler. 
(3) Price quoted will be determined acc. to request. Prices differ depending on the service. Given price is the lowest calibration price 
(4)  



HARDNESS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2ST-1100  Rockwell / Calibration of Hardness Reference Blocks 
G2ST-1300  Brinell / Calibration of Hardness Reference Blocks 
G2ST-1500  Vickers / Calibration of Hardness Reference Blocks 
G2ST-5300  Rockwell Conical Diamond Indenters for Rockwell A, C, D, N Scales 
G2ST-5500  Vickers Pyramid Diamond Indenters 
G2ST-9900  Special Calibration / Test  2, 3 
(1) The service is in the acrreditation scope. 
(2) In case of outside calibration, accommodation and traveling costs are under responsibility of customer. 
(3) Price will be determined according to the request and the standards. 



HIGH VOLTAGE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1YG-1050  DC High Voltage Measuring System Calibration (100 kV - 400 kV)  1, 2, 3, 7,11 
G1YG-1250  DC High Voltage Measuring System/Probe Calibration (1 kV - 100 kV)  1, 2, 3, 7, 11 
G1YG-2050  AC High Voltage Measuring System Calibration (45 Hz-60 Hz, 101 kV - 400 kV)  1, 2, 3, 9, 11 
G1YG-2555  Calibration of High Frequency High Voltage Measuring System (50 Hz-300 Hz, 1 kV-200 kV)  2, 3, 9, 11 
G1YG-2655  Calibration of VLF (Very Low Frequency) AC High Voltage Device (1 kV-120 kV)  2, 3, 9, 11 
G1YG-2800  Calibration of AC High Voltage Measuring System (45 Hz-60 Hz, 1 kV - 100 kV)  1, 2, 3, 9 
G1YG-3050  Lightning Impulse High Voltage Measuring System Calibration (40kV - 1000kV)  1, 2, 3, 11 
G1YG-3100  Switching Impulse High Voltage Measuring System Calibration (40kV - 850kV)  1, 2, 3, 11 
G1YG-3200  Impulse High Voltage Measuring System/Probe Calibration (<40 kV)  1, 2, 3, 11 
G1YG-3250  Impulse High Voltage Source Calibration (1 kV - 40 kV) (Includes volatge and current option)  1, 2, 3, 11 
G1YG-3260  Calibration of Impulse High Current Shunt/Probe  2, 3, 11 
G1YG-4400  PD Detector Calibration (>2 pC)  1, 2, 3, 11 
G1YG-4450  PD Calibrator Calibration  1, 2, 3, 11 
G1YG-4451  Surge Device Calibration  2, 3, 11 
G1YG-4452  Electrostatic Field Meter Calibration  2, 3, 11 
G1YG-5060  Calibration of Capacitance and Dissipation Factor Measuring Device  1, 2, 3, 4, 11 
G1YG-5070  Calibration of Standard Capacitor  1, 2, 3, 4, 11 
G1YG-6000  Calibration of Oil Tester  1, 2, 3, 11 
G1YG-6025  Insulation Tester Calibration (up to 10 kV, Meger etc.)  1, 2, 3, 7, 8, 11 
G1YG-6050  Calibration of High Voltage Field Meter  1, 2, 3, 11 
G1YG-9900  Special High Voltage Test/Measurements  2, 3, 5, 6, 10 
(1) All our activities are peformed according to IEC 60060-2 standard. 
(2) The calibrations have been priced for five measuring points at least. For the each additional measuring point, 10% of extra charge will be added to the calibration fee. 
(3) Customer is responsible to supply the uninterrupted source for on-site calibration according to the IEC 60060-1 and IEC 60060-2. No any repay in the case of problem about breakdown, out of system etc. 
(4) C/tand measurement and calibrations performed in the TÜBİTAK UME High Voltage Laboratory under (50 Hz) AC high voltage and up to 400 kV. On site C/tand measurement and calibrations performed maximum up to 10kV.. 
(5) Opening hours are 08:00 to 12:00 and 13:00 to 16:30. 
(6) Pricing is based on demand. 
(7) Calibration cost for one polarty.For double polarty %50 calibration cost is added. 
(8)  
(9) Our accreditation scope can be reached from TÜRKAK web site (www.turkak.org.tr). 
(10)  
(11)  



HUMIDITY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1NM-1000  Calibration of Dew-Point Hygrometer (-30 °C / +60 °C ; at 4 calibration points)  1, 2, 3, 6 
G1NM-1500  Calibration of Dew-Point Hygrometer (-40 °C / +10 °C ; at 3 calibration points)  1, 2, 3, 6 
G1NM-1600  Calibration of Dew-Point Hygrometer (-80 °C / +10 °C ; at 3 calibration points)  1,2,3,6 
G1NM-2000  Calibration of Hygrometer Relative Humidity (3 relative humidity calibration points at one temperature value)  1, 2, 3, 6 
G1NM-2100  Calibration of Hygrometer Relative Humidity (3 relative humidity calibration points at one temperature value in the climatic chamber)  1, 2, 3, 6 
G1NM-2500  Calibration of Hygrometer Temperature ( 3 temperature calibration points at one relative humidity value)  1, 2, 3, 6 
G1NM-2600  Calibration of Hygrometer Temperature ( 3 temperature calibration points at one relative humidity value in the climatic chamber)  1, 2, 3, 6 
G1NM-3000  Calibration of Relative Humidity Chamber (at 1 relative humidity calibration point)  1, 2, 3, 6 
G1NM-4000  Calibration of Psychrometer (at 3 calibration points)  1, 2, 3, 6 
G1NM-5000  Humidity Characterization of Climatic Chamber (one calibration point)  1, 2, 6 
G1NM-5100  Humidity Calibration of Climatic Chambers (at 3 calibration points)  1, 2, 6 
G1NM-5500  Air Temperature Characterization of Climatic Chamber (From -40 °C to 100 °C, one calibration point)  1, 2, 6 
G1NM-5600  Air Temperature Calibration of Climatic/Temperature Chambers (at 3 calibration points)  1, 2, 6 
G1NM-6000  Moisture content determination in materials (Paper and solid biomass)(at 3 calibration points)  1,3,4,6,7 
G1NM-9900  Special Calibration / Test  2, 3, 4, 5, 6 
(1) This item is in the scope of accreditation. 
(2) Please specify dew-point temperature, relative humidity, and air temperature values in your calibration request. The technical manual of the device to be calibrated, previous calibration certificates, and related documents should be sent together with the device. 
(3) Please send the device including all components i.e. connection and power cables, spare battery, software together with PC, etc. ready for measurements. Please specify clearly if your instrument works with power supply other than 220 VAC. 
(4) Please send the samples you use and/or standards you apply. 
(5) Price will be determined according to technical requirements. 
(6) Please note that laboratory will not be held responsible not only for any damages occurring to the equipment during the calibration process but also during the transportation. 
(7) Moisture content determination is carried out only for paper based and solid biomass materials. 
()  
()  



INORGANIC LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G3IK-3001  Determination of As in Sea Fish 
G3IK-3002  Determination of Hg in Sea Fish 
G3IK-3003  Determination of As in Herb 
G3IK-3004  Determination of Ca in Herb 
G3IK-3005  Determination of Cd in Herb 
G3IK-3006  Determination of Pb in Herb 
G3IK-3007  Determination of Zn in Herb 
G3IK-3008  Determination of Pb in Wine 
G3IK-3009  Determination of Zn in Soybean 
G3IK-3010  Determination of Zn in Soybean 
G3IK-3011  Determination of AsB   
G3IK-3012  Determination of Cu in Ethanol   
G3IK-3013  Determination of Cu in Infant Formula 
G3IK-3014  Determination of I in Infant Formula 
G3IK-3015  Determination of K in Infant Formula 
G3IK-3020  Determination of elements in hazelnut 
G3IK-3101  Determination of Sr in Sea Water 
G3IK-3102  Determination of Na in Sea Water 
G3IK-3103  Determination of Mg in Sea Water 
G3IK-3104  Determination of Ca in Drinking Water 
G3IK-3105  Determination of Cd in Drinking Water 
G3IK-3106  Determination of Ni in Drinking Water 
G3IK-3107  Determination of Pb in Drinking Water 
G3IK-3108  Determination of Pb Isotopic Composition in Water   
G3IK-3109  Determination of As in Drinking Water 
G3IK-3110  Determination of B in Drinking Water 
G3IK-3111  Determination of Cr in Drinking Water 
G3IK-3112  Determination of Mo in Drinking Water 
G3IK-3113  Determination of Cr(VI) in Drinking Water   
G3IK-3114  Determination of Se in water 
G3IK-3120  Determination of elements in sea water 
G3IK-3130  Determination of elements in waste water 
G3IK-3201  Determination of (SO42-) in sea water   
G3IK-3204  Determination of Pb in Salt Solutions 
G3IK-3205  Determination of Pb Isotopic Composition in Salt Solutions   
G3IK-3301  Determination of As in biological materials 
G3IK-3302  Determination of Pb in Biological Materials 
G3IK-3303  Determination of Cr in Biological Materials 
G3IK-3304  Determination of Ni in Algae 
G3IK-3305  Determination of Ni in Algae 
G3IK-3306  Determination of K in Human Serum 
G3IK-3307  Determination of Ca in Human Serum 
G3IK-3308  Determination of Mg in human serum 
G3IK-3309  Determination of Fe in Human Serum 
G3IK-3310  Determination of Selenomethionine in Human Serum   
G3IK-3311  Determination of Cl in Serum 
G3IK-3312  Determination of Cu in Serum 
G3IK-3313  Determination of Na in Serum 
G3IK-3314  Determination of P in Serum 
G3IK-3315  Determination of Se in Serum 
G3IK-3316  Determination of As in Leather 
G3IK-3317  Determination of Cd in Leather 
G3IK-3318  Determination of Pb in Leather 
G3IK-3319  Determination of TBT in leather   
G3IK-3320  Determination of Hg in biological materials 
G3IK-3321  Determination of Ni in biological materials 
G3IK-3322  Determination of P in biological materials 
G3IK-3323  Determination of Zn in biological materials 
G3IK-3401  Determination of Ag in Metallic Zinc 
G3IK-3402  Determination of Al in Metallic Zinc 
G3IK-3403  Determination of Cd in Metallic Zinc 
G3IK-3404  Determination of Cr in Metallic Zinc 
G3IK-3405  Determination of Ni in Metallic Zinc 
G3IK-3406  Determination of Tl in Metallic Zinc 
G3IK-3407  Determination of Total Impurity in Metallic Zinc   
G3IK-3408  Determination of Pb Isotopic Composition in Bronze   
G3IK-3420  Detection and determination of impurities in metals and alloys   
G3IK-3421  Determination of O, N and H in metals and alloys   
G3IK-3422  Determination of C and S in metals and alloys   
G3IK-3501  Determination of Co in Single Element Calibration Solution   
G3IK-3601  Determination of As in cosmetic material 
G3IK-3602  Determination of Pb in Cosmetic Material 
G3IK-3603  Determination of Hg in Cosmetic Material 
G3IK-3701  Determination of Ca in Biodiesel Fuel 
G3IK-3702  Determination of K in Biodiesel Fuel 
G3IK-3703  Determination of Mg in Biodiesel Fuel 
G3IK-3704  Determination of Na in Biodiesel Fuel 
G3IK-3705  Determination of P in Biodiesel Fuel 
G3IK-3710  Determination of S in diesel   
G3IK-3801  Determination of As in Soil 
G3IK-3802  Determination of Cd in Soil 
G3IK-3803  Determination of Fe in Soil 
G3IK-3804  Determination of Mn in Soil 
G3IK-3805  Determination of Pb in Soil 
G3IK-3900  Determination of elements in bor minerals 
G3IK-9900  Special Calibration / Test 
(1) Price to be added for measurement of each additional parameter in the sample is 61 TL. 
(2) Price depends on the requirements. 
()  



MAGNETICS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1MA-1110  Characterization of permanent magnets   
G1MA-3100  Reference magnets   
G1MA-4100  Field Coils   
G1MA-5110  Magnetometers (1 measurement range)   
G1MA-5120  Magnetometers (2 measurement ranges)   
G1MA-5130  Magnetometers (3 measurement ranges)   
G1MA-5140  Magnetometers (4 measurement ranges)   
G1MA-5150  Magnetometers (5 and more measurement ranges)   
G1MA-6100  Fluxmeters   
G1MA-7100  Magnetic stripes on identification cards   
G1MA-9900  Special Calibration / Test 
(1) Cost of the service is determined based on your request. 



MASS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2KU-1110  E1 Class 1 mg- 1 kg 
G2KU-1150  E2 Class 1 mg - 1 kg 
G2KU-1210  E1 Class 2 kg - 10 kg 
G2KU-1250  E2 Class 2 kg - 10 kg 
G2KU-1310  E1 Class 20 kg - 50 kg 
G2KU-1350  E2 Class 20 kg - 50 kg 
G2KU-1450  E2 Class over 50 kg 
G2KU-5300  Determination of volume or density of solids in the range of 1 g – 1 kg   
G2KU-5400  Determination of volume or density of solids in the range of 2 kg– 10kg   
G2KU-5500  Determination of volume or density of solids in the range of 20kg– 50 kg   
G2KU-9900  Special Calibration / Test 
(1) In case of volume determination of the weight, % 50 of the calibration price will be added to the total price. 
() The price will be determined according to the request and the standards. 



ORGANIC CHEMISTRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G3OK-10000     
G3OK-10100     
G3OK-10200     
G3OK-10300     
G3OK-10400     
G3OK-10500     
G3OK-10600     
G3OK-2000  Determination of δ2H/1H, δ18O/16O ratio in water by IR-MS   
G3OK-2200  Determination of δ13C/12C ratio in sugar by IR-MS   
G3OK-2400  Analysis of δ13C/12C in honey and grape molasses by IRMS   
G3OK-2500  Determination of ?15C/14N ratio in Fish muscle by IR-MS   
G3OK-4000  Determination of Chloramphenicol in Meat   
G3OK-4001  Determination of Chloramphenicol in Milk   
G3OK-4002  Determination of Chloramphenicol in Honey   
G3OK-4101  Determination of Tetracycline Group Antibiotics in Meat   
G3OK-4102  Determination of Tetracycline Group Antibiotics in Milk   
G3OK-4201  Determination of Sulphonamide Group Antibiotics in Meat   
G3OK-4202  Determination of Sulphonamide Group Antibiotics in Milk   
G3OK-4300  Purity Assesment of Organic Compounds   
G3OK-4400  Purity Assesment of Chloramphenicol   
G3OK-4500  Determination of Chlorinated Pesticides in Tea   
G3OK-4600  Determination of 3-epi-25-Hydroxyvitamin D3 in Serum   
G3OK-4610  Determination of vitamine 25-OH D2   
G3OK-4620  Determination of vitamine 25-OH D3   
G3OK-4700  Determination of Coenzyme Q10 in food supplements   
G3OK-4801  Determination of Water-Soluble Vitamines in food supplements (B1, B2, B3, B5, B6, B9, B12, C) 
G3OK-4802  Determination of Fat Soluble Vitamines in food supplements (A, D3, E) 
G3OK-4900  Determination of Methyl Sulfonyl Methane (MSM) in food supplements   
G3OK-5000  Determination of EPA, DHA and total oil (fish oil) in fish oil   
G3OK-5200  Determination of Chondroitine in food supplements   
G3OK-5300  Determination of Glucosamine in food supplements   
G3OK-5400  Determination of beta 1,3-1,6 glucan in food supplements   
G3OK-5600  Determination of Cholesterol in Serum   
G3OK-5700  Determination of Glucose in Serum   
G3OK-5800  Determination of Creatinine in Serum   
G3OK-6000  Determination of Benzoic Acid, Methy Paraben, n-Butyl Paraben,Sorbic Acid and Propionic Acid in Soya Sauce, Water, Aqueous-Based Beverages and Aqueous-Based Condiments 
G3OK-6200  Determination of Sodium Benzoate and Potassium sorbate in Food and Beverages 
G3OK-6300  Determination of Sodium Benzoate and Potassium sorbate in Ketchup 
G3OK-6400  Determination of ?-cyanoalanine (BCA) and ?-glutamyl ?-cyanoalanine (?GBCA) in Lentil 
G3OK-6500  Determination of BDE-47 in Sediment   
G3OK-6600  Determination of PAH in Organic Solutions   
G3OK-6700  Determination of PAH in Plant Matrices   
G3OK-6800  Determination of AFB1, AFB2, AFG1, AFG2 and Total AF in Dried Fig   
G3OK-6900  Determination of Urea and Uric Acid in Biological Matrix   
G3OK-7000  The measurement of National Marker, return and disposal procedures 
G3OK-7100  Determination of Enrofloxacin and Sulfadiazine in Meat   
G3OK-7200  Determination of Amino asid in Aqueous Solution   
G3OK-7300  Determination of Ethanol in Water   
G3OK-7400  Determination of Specific Adsorption of Nonporous Silicon Dioxide (Sio2) and BET Specific Surface Area   
G3OK-7500  Determination of PAH in Vegetable oils   
G3OK-7600  Determination of Phthalate Esters in Polyvinyl Chloride   
G3OK-7700  Determination of Zearolenone in Acetonitrile   
G3OK-7800     
G3OK-7900     
G3OK-8000  Determination of d13C/12C ratio in Vanillin by IR-MS   
G3OK-8400     
G3OK-8500     
G3OK-8600     
G3OK-8700     
G3OK-8800     
G3OK-8900     
G3OK-9000     
G3OK-9100     
G3OK-9200     
G3OK-9300     
G3OK-9400     
G3OK-9500     
G3OK-9600     
G3OK-9700     
G3OK-9800     
G3OK-9900  Special Calibration / Test 
(1) Price depends on the requirements. 
(2) Price is given per analyte. 



PHOTOVOLTAIC PERFORMANCE TESTS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1FV-0100  Visual Inspection Experiment  1, 2, 3, 4, 10, 12 
G1FV-0200  Maximum Power Experiment  2, 3, 4, 5, 6 
G1FV-0250    2, 3, 4, 5, 6 
G1FV-0300  Insulation Resistance Experiment  3, 4 
G1FV-0400  Temperature Coefficient Experiment  3, 4, 6, 7, 12 
G1FV-0500  Nominal Module Operating Temperature (NMOT) Experiment  3, 4 
G1FV-0600  Performance Test of Module at STC and NMOT Conditions  3, 4, 5, 6, 12 
G1FV-0700  Low Irradiance Performance Experimet  3, 4, 5, 6, 12 
G1FV-0800  Outdoor Exposure Experiment  3, 4 
G1FV-0900  Hot-Spot Endurance Experiment  1, 2, 3, 4, 5, 6 
G1FV-1000  UV Preconditioning Experiment (15 kWh)  1, 2, 3, 4, 5, 6, 12 
G1FV-1100  Thermal Cycling Experiment  1, 2, 3, 4, 5, 6 
G1FV-1200  Humidity Freeze Experiment  1, 2, 3, 4, 5, 6 
G1FV-1300  Damp Heat Experiment  1, 2, 3, 4, 5, 6 
G1FV-1400  Robustness of Terminations Experiments  1, 2, 3, 4, 5, 6 
G1FV-1500  Wet Leakage Current Experiment  1, 2, 3, 4, 5, 6 
G1FV-1600  Mechanical Load Experiment  1, 2, 3, 4, 5, 6, 12 
G1FV-1650    1, 2, 3, 4, 5, 6, 12 
G1FV-1700  Hail Experiment  1, 2, 3, 4, 5, 6, 12 
G1FV-1800  Bypass Diode Thermal  1, 2, 3, 4, 5, 6 
G1FV-1850  Bypass Diode Functionality Experiment  1, 2, 3, 4, 5, 6, 12 
G1FV-1900  Stabilisation Experiment  1, 2, 3, 4, 5, 6, 12 
G1FV-2000  Accessibility Experiment  1, 2, 3, 4, 5, 6 
G1FV-2100  Cut Susceptibility Experiment  1, 2, 4 
G1FV-2200  Ground Continuity Experiment  1, 2, 4 
G1FV-2300  Impulse Voltage Experiment  1, ,2, 4 
G1FV-2400  Tempereture Experiment  11 
G1FV-2500  Fire Experiment  11 
G1FV-2600  Reverse Current Overload Experiment  1, ,2, 4 
G1FV-2700  Module Breakage Deneyi  1, ,2, 4 
G1FV-2800  Materials Creep Experiment  11 
G1FV-2900  UV Experiment  1, ,2, 4 
G1FV-3000  Cold Conditioning Experiment  11 
G1FV-3100  Dry Heat Conditioning Experiment  11 
G1FV-3200  Spectral Responsivity Experiment  1, 2, 3, 5, 6, 12 
G1FV-3300  Light Induced Degradation (LID) Experiment  11 
G1FV-3400  Potantial Induced Degradation (PID) Experiment  8, 11 
G1FV-3500  Energy Rating Experiment  9, 11 
G1FV-3600  Reference Cell Calibration  2, 3, 5 
G1FV-3700  Simulator Classifications   5, 7 
G1FV-9900  Special Calibration / Test  11 
(1) The experiment is performed according to IEC 61215-2 standard. 
(2) The experiment is performed according to IEC 61730-2 standard. 
(3) The experiment is performed according to IEC 61730-2 standard. 
(4) The experiment is performed according to IEC 61853-1 standard. 
(5) The experiment is performed according to IEC TS 61853-2, Method A standard. 
(6) The price will be evaluated with respect to the experiments sequence given in the standard 
(7) The experiment is performed according to IEC TS 62804-1, Method A standard. 
(8)  
(9)  
(10)  
(11)  
(12)  



POWER AND ENERGY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1PE-1200  Wattmeter/Energymeter Calibration (by AC Power Measurement Standard) 
G1PE-1210  Wattmeter/Energymeter Calibration (by Three Phase Standard Wattmeter/Energymeter) 
G1PE-1300  Power/Energy Analyzer Calibration (by Three Phase Standard Wattmeter/Energymeter) 
G1PE-1310  Power/Energy Analyzer Calibration (by Electrical Power Standard) 
G1PE-1510  Electricity Meter Calibration (Single or Three Phase), Active 
G1PE-1520  Electricity Meter Calibration (Single or Three Phase), Reactive 
G1PE-1700  Phase Meter Calibration   
G1PE-1800  Phase Standard Calibration   
G1PE-1920  AC Power Source Calibration, Three Phase 
G1PE-2000  Electrical Power Standard Calibration 
G1PE-5000  Current Transformer Calibration (Ratio and Phase Error) 
G1PE-5010  Multiratio Current Transformer Calibration  1, 2 
G1PE-5100  Current Transformer Test Set Calibration 
G1PE-5200  Standard Current Burden Calibration 
G1PE-6000  Voltage Transformer Calibration (Ratio and Phase Error) 
G1PE-6010  Multiratio Voltage Transformer Calibration  1, 2 
G1PE-6100  Voltage Transformer Test Set Calibration 
G1PE-6200  Standard Voltage Burden Calibration 
G1PE-9810  Transformer Loss Measurement System Calibration (On-site)  1, 2 
G1PE-9900  Special Calibration / Test 
(1) The service is in the acrreditation scope. 
(2) Price depends on the requirements. 



PRESSURE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2BA-1100  Determination of Effective Area of Piston-Cylinder Unit  1,2,3,6 
G2BA-2100  Analogue Manometer Calibration  1,2,4,6 
G2BA-2110  Absolute Analogue Manometer Calibration  1,2,6 
G2BA-2200  Digital Manometer Calibration  1,2,4,6 
G2BA-2210  Absolute Digital Manometer Calibration  1,2,6 
G2BA-2500  Pressure Transducer Calibration  1,2,4,6 
G2BA-2510  Absolute Pressure Transducer Calibration  1,2,6 
G2BA-3100  Manometer Calibrator Calibration (Per Measuremet Range)  1,2,4,6 
G2BA-3110  Absolute Manometer Calibrator Calibration (Per Measuremet Range)  1,2,4,6 
G2BA-4100  Analogue Barometer Calibration  1,2,6 
G2BA-4200  Digital Barometer Calibration (from 800 hPa to 1200 hPa absolute )  1,2,6 
G2BA-6100  Air Data Test Set Calibration (Per Measurement Range)  1,2,6 
G2BA-9900  Special Calibration / Test  2,5,6 
(1) Accredited Item 
(2) '20 percent of calibration fee is demanded in case of the instrument is not clean enough for the calibration.for DWT and vacuum gages. For the defective instrument determined by the tests (at about 20 hours later), 50 percent of calibration fee is demanded for vacuum gages. 
(3) Conventional mass values and its uncertainties will be given in the certificate of mass set of pressure balance 
(4) Only the calibration request for the pneumatic pressure ranges from 0 bar to (-1) bar and the range above 20 bars and for the hydraulic pressure range above the 700 bars will be responded. 
(5) Price is determined according to the specification of the demanded measurement. 
(6) Calibration fees announced are per measurement range or per sensor or per piston-cylinder unit 
()  
()  



QUANTUM METROLOGY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1KM-9900  Custom Measurements and Experiments  1-22 arası tüm notlar 
(1)  
(2)  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  
(10)  
(11)  
(12)  
(13)  
(14)  
(15)  
(16)  
(17)  
(18)  
(19)  
(20)  
(21)  
(22)  



RADIATION THERMOMETRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1RS-1000  Calibration at Fixed-Point Blackbody  1, 2, 3 
G1RS-2000  Radiation Thermometer Calibration (-50 °C / 800 °C)  1, 2, 3, 4, 6 
G1RS-2100  Radiation Thermometer Calibration (800 °C / 1600 °C)  1, 2, 3, 4, 6 
G1RS-2200  Radiation Thermometer Calibration (1600 °C / 2600 °C)  1, 2, 3, 4, 6 
G1RS-2300  Radiation Thermometer Calibration (2600 °C / 3200 °C)  1, 2, 3, 4, 6 
G1RS-3000  Blackbody/IR Calibrator Calibration (-50 °C / +1600 °C)  1, 2, 3, 4, 6 
G1RS-4000  Infrared Forehead Thermometer Calibration (34 °C / 42 °C)  2, 4, 7, 8 
G1RS-9900  Special Calibration / Test  2, 3, 4, 5, 6, 7 
(1) Acredited Calibration. 
(2) Please note that laboratory will not be held responsible for any damages occurring to the equipment during the calibration and transportation process 
(3) Please specify the calibration temperature range in the calibration request form and send all relevant documents (manuals, past certificates etc) and accessories of the instrument 
(4) The price is given for a measurement at single temperature. 
(5) Price will be determined according to technical requirements demanded by the customer. 
(6) For the devices requiring electronic circuit connections;1- The customer shall send their employee to UME to make the connections 2- The customer must assume all responsibility for any adverse circumstances/incidents that may occur due to the connections during the measurements. 
(7) For IR calibrators and Black bodies, only emissivity measurements or only surface temperature measurements are not performed. They are performed together with the calibration application. 
(8) The emissivity measurements can only be performed for temperatures higher than 150 ° C. 



RADIOMETRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1RA-4100  UVA Irradiance Meter 
G1RA-4120  Total UVB Irradiance Responsivity (280 nm - 315 nm) 
G1RA-4130  Total UVC Irradiance Meter (200 nm - 280 nm)   
G1RA-4150  Spectral Irradiance Responsivity ( 280 nm-1100 nm)   
G1RA-4200  Spectral Irradiance of Sources, (W/m2 ), (250 nm-2500 nm)   
G1RA-4300  Solar Irradiance Meter (200nm-1100nm)   
G1RA-4400  Pyranometer 
G1RA-4600  Pyrheliometer 
G1RA-4700  Spectral Radiance Responsivity   
G1RA-4800  Spectral Radiance   
G1RA-6400  Pulsed Laser Energy (1064 nm, <= 150 mJ) 
G1RA-6500  Laser Power Meter 
G1RA-6700  Spectral Responsivity (380 nm-1100 nm)   
G1RA-6800  Spectral Responsivity (1100 nm-1650 nm)   
G1RA-6900  Spectral Responsivity (250 nm-380 nm)   
G1RA-9900  Special Calibration / Test 
(1) Calibration of a UVA detector is carried out under Spectroline SB-100P/F model irradiance lamp supported with a UV filter (Spectronics Corporation, model 2F958). Typical calibration points are 100 uW/cm^2, 500 uW/cm^2, 1000 uW/cm^2, 2000 uW/cm^2 and 3000 uW/cm^2. 
(2) Calibration of a UVB radiometer is carried out under a deuterium light sources. 
(3) Measurements are carried out at provided environmental conditions (June - September) 
(4) The calibration is performed at 355 nm, 532 nm and 1064 nm pulse wavelengths and at an energy range of 10 mJ to 200 mJ. The calibration fee is valid for only one wavelength. 
(5) The calibration is performed at 488 nm, 515 nm, 532 nm, 633 nm and 1064 nm laser (CW) wavelengths and at optical power range of 10 mW to 1000 mW. The price is valid only for measurements of two wavelengths. 
(6) The price will be determined according to technical requirements. 



REFERENCE MATERIALS LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G3RM-1101  "Particle Size Distribution Analysis with Laser Diffraction Method (0.02 µm-2000 µm)- Analysis of Powder in Dispersant or Direct Analysis of the Powder by Dry Suction Unit "   
G3RM-1102  Particle Size Distribution Analysis with Vibrating Dry Sieving (Up to 8 Sieves) (45 µm-2000 µm)   
G3RM-1103  Particle Size Distribution Analysis with Air Jet Dry Sieving (Up to 8 Sieves) (45 µm-2000 µm)   
G3RM-1104  Homogenisation (solid powder materials, one batch maximum 250 kg/250 Liters) 
G3RM-1105  Liyophilisation (one batch maximum 3.9 m2 shelf surface area and 40 kg ice condensing capacity) 
G3RM-1106  Determination of Aflatoksin B1, B2, G1, G2 and Total in Dried Fig by HPLC -FLD (with immunoaffinity purification and cobra cell derivatization)   
G3RM-9900  Special Calibration / Test 
(1) Price depends on the requirements. 



RF & MICROWAVE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1MD-1000  Primary level power sensor calibration (up to 26.5 GHz)  1, 2 
G1MD-1100  Calibration Factor of RF power sensor or thermistor mount (up to 15 frequency)  1, 2 
G1MD-1300  RF power meter calibration 
G1MD-1500  RF power measurement  1, 4 
G1MD-2100  Transmission Coefficient (up to 60 dB, 45 MHz-26,5 GHz) (up to 20 frequencies)  1, 5, 6 
G1MD-3000  Primary Level Calculable Impedance Standard (airline) Calibration (up to 50 GHz) 
G1MD-3100  Reflection coefficient, VSWR, return loss measurement (45 MHz-26,5 GHz) (up to 20 frequencies)  1, 6 
G1MD-3300  Network analyzer calibration  8, 9 
G1MD-4100  G1MD-4100 Directional Coupler Calibration (<=2 GHz)  6, 10 
G1MD-4200  Coaxial Calibration Kit Calibration  6, 11 
G1MD-4300  Waveguide Calibration Kit Calibration  6, 11 
G1MD-4400  Measurement of Dielectric Properties of Materials (up to 50 GHz)  12, 13, 14 
G1MD-4500    6, 10 
G1MD-5100  Noise Source Calibration (up to 50 GHz)  10, 14 
G1MD-8100  Mobile Phone SAR Test (900 MHz, 1800 MHz)  11, 15 
G1MD-9900  Special Calibration / Test  12, 16 
(1) Accredited item. 
(2) If more frequency points are requested, 180 TL is added for each extra frequency point to the price. 
(3) Price depends on the requirements. 
(4) It is valid for three different traffic channel for one SIM card and one frequency (900 MHz or 1800 MHz) point. 
(5)  
(6)  
(7)  
(8)  
(9)  
(10)  
(11)  
(12)  
(13)  
(14)  
(15)  
(16)  



SPECTRO PHOTOMETRY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1SP-1100  Luminous Flux (Tungsten Lamps, 2856 K), (5 lm-5000 lm)   
G1SP-1150  Spectral Luminous Flux ( LED and SSL Lamps with max. 10 cm size), (0,7 lm-30000 lm)   
G1SP-1500  Luminous Intensity (1 cd-10000 cd) 
G1SP-1550  Spatial Luminous Intensity ( Tungsten, LED and SSL Lamps with 2 cm size) 
G1SP-2100  Color Coordinates of Light Sources, (CIE-xy, CIE-u'v')   
G1SP-2300  Color Temperature of Light Sources (2856 K) 
G1SP-2500  Color Plate (CIEXYZ, CIExy, CIELAB, DeLtaE), 0°:45° 
G1SP-2700  Color Plate (CIEXYZ, CIExy, CIELAB, DeltaE), d:0° and d:8° 
G1SP-2900  Colorimeter (DeltaE), 0°:45° and d:8° 
G1SP-3100  Luminance Responsivity (Luminance Meter), (1 cd/m2-1000 cd/m2) 
G1SP-3300  Luminance Source (27 cd/m2-5000 cd/m2)   
G1SP-3500  Illuminance (Luxmeter), (0,1 lx - 5000 lx) 
G1SP-3600  Luminous Responsivity (Photometer Head), (0,0002 nA/lx - 10 mA/lx)   
G1SP-5000  Spectral Regular Reflectance 
G1SP-5300  Gloss (Gloss/ Gloss Plate) 
G1SP-5500  Spectral Diffuse Reflectance 
G1SP-6000  Absolute Diffuse Reflectance (250 nm-2500 nm) 
G1SP-7000  Spectrophotometer (UV/VIS)   
G1SP-7100  Spectral Regular Transmittance 
G1SP-7300  Total Transmittance 
G1SP-7400  Wavelength Measurements of Light Sources   
G1SP-7500  Diffuse Transmittance Meter (Densitometer) 
G1SP-7600  Diffuse Transmittance (Step Density Strip / Film) 
G1SP-9900  Special Calibration / Test 
(1) The price given is valid for single solid angle and single ray direction. 
(2) Calibration is performed only at 2856 K color temperature. 
(3) Only valid for one type of lightning condition 
(3) Only valid for one type of lightning condition 
(4) The illuminance measurements are carried out at 50 lx, 500 lx , 800 lx and 2000 lx levels. If the customer request measurements at different points, it must be stated during the application. The extra measurement points between 0,1 lx and 4000 lx are subjected to a separate pricing per each additional measurement point. 
(5) The price is valid for one of the two wavelength ranges listed below and applies to a single bandwidth (SBW). 1) 250 nm - 1100 nm 2) 1100 nm - 2500 nm Two separate demands are required for neutral density filters and wavelength accuracy filters located in the same box.  
(6) The price is valid for the angles of 20°, 60°, and 85° 
(7) The price will be determined according to the measurement conditions and customer request. 
(8)  
(9)  



SURFACE TEXTURE AND NANOMETROLOGY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2BY-0100  Roughness Standard  1,2 
G2BY-0110  Depth Setting Standard 
G2BY-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) Measurements are performed for one Cut-Off value. If more than one Cut-Off measurements are requested, 260 TLs for each Cut-Off value must be added to the price. 
(3) Price quoted will be determined acc. to request. Prices differ depending on the service. 



TIME / FREQUENCY AND WAVELENGTH LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1ZF-1100  Atomic Time and Frequency Standard   
G1ZF-1300  Stability Measurement of Laser Frequency   
G1ZF-1310  Interferometric Long Gauge Block Measurement 
G1ZF-1500  Quartz Time and Frequency Standard   
G1ZF-2100  Timer - Counter   
G1ZF-2500  Synthesized Sweeper / Signal Generator   
G1ZF-3100  Spectrum Analyzer   
G1ZF-3300  EMC Test Equipment (Burst / Discontinuous Interference Analyzer)   
G1ZF-3400  Audio Analyzer   
G1ZF-3800  Measurement Receiver   
G1ZF-9900  Special Calibration / Test 
(1) Pricing is determined with respect to the tests to be performed. 
(2) Per piece 



TOPOGRAPHIC AND INDUSTRIAL MEASUREMENTS CALIBRATION / TEST LIST

CODE NAME NOTE
G2BT-0100  Theodolite 
G2BT-0200  Optical Level  1,2 
G2BT-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) If optical level has optical micrometer, price of each micrometer is 200 TL. 
(3) Price quoted will be determined acc. to request. Prices differ depending on the service. 



TORQUE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2TK-1100  Calibration of Torque Transducers  1,2 
G2TK-2200  Static Calibration of Indicating Torque Wrenches  1, 4 
G2TK-3100  Calibration of Hand Torque Tools  1, 5 
G2TK-4100  Calibration of Torque Wrench Calibration Devices (for each measuring range)  1, 6, 8 
G2TK-9900  Special Calibration / Test 
(1) The service is in the acrreditation scope. 
(2)  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  



VACUUM LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2VK-1100  Pirani, Thermal Conductivity, Thermocouple Type Vacuum Gauges  1, 2, 3 
G2VK-1200  Capacitance Diaphragm Type Vacuum Gauges (CDG)  1, 2 
G2VK-2100  Cold and Hot Cathode Type Vacuum Gauges  1, 2, 3 
G2VK-2200  Spinning Rotor Type Vacuum Gauges  1, 2, 3 
G2VK-3100  Full Range Vacuum Gauges  1, 2, 3 
G2VK-5100  Hellium Leak rate detection in vacuum (1,1 E-5 mbarl/s - 2E-8 mbarl/s)  4, 5 
G2VK-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) 20 percent of calibration fee is demanded in case of the vacuum gauge is not clean enough for the calibration.If the vacuum gauge is found to be defective through tests (at least 16 hours) , 50 percent of calibration fee is demanded. 
(3)  
(4)  
(5)  
(6)  



VIBRATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2TI-1100  Absolute Calibration of Standard Reference Accelerometers by Laser Interferometry ( (Calibration at 1/3 octave band center frequencies in the frequency range 10 Hz to 10 kHz) 
G2TI-1500  Comparison Calibration of Accelerometers (at 160 Hz) and Determination of Frequency Response  2,6 
G2TI-1800  Absolute Calibration of Shock Transducers by Laser Interferometry 
G2TI-1900  Comparison Calibration of Shock Transducers 
G2TI-2100  Calibration of Vibration Exciter (Calibration at each frequency other than 159.15 Hz is performed at additional cost of 440 TL).   
G2TI-2200  Calibration of Vibration Measuring Set Calibration performed at the frequency of 160 Hz. Calibration at each frequency other than 160 Hz is performed at additional cost of 550 TL 
G2TI-3100  Calibration of Impact Hammer   
G2TI-4100  Measurement of Mechanical Vibrations (Total Amplitude) (up to 10 measurement points)  3,4 
G2TI-4200  Frequency Analysis of Mechanical Vibrations (up to 10 measurement points)  3,4 
G2TI-5100  Measurement of Gravity Acceleration  5, 7 
G2TI-6100  Calibration of Conditioning Amplifier 
G2TI-7100  Calibration of Impedance Head (Calibration at 1/3 octave band center frequencies in the frequency range 100 Hz to 8 kHz)   
G2TI-9900  Special Calibration / Test  3,4,5 
(1) Calibration at each frequency other than 160 Hz is performed at additional cost of 125 TL 
(2) Calibration cost for triaxial accelerometers and vibration meters with triaxial accelerometer is two times of the single axis calibration price. 
(3) Acredited Service for hand-arm vibration measurement. 
(4) Cost of the service is determined based on your request. 
(5) Accomodation and trasportation costs are added to the measurement cost 
(6)  
(7)  
(8)  



VISKOSITY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2VI-1100  Determination of Kinematic Viscosity of Newtonian liquids in the range of 0,5 - 100 000 mm²/s 
G2VI-1200  Determination of Dynamic Viscosity of Newtonian liquids in the range of 0,5 - 100 000 mPa·s 
G2VI-1300  Determination of Viscometer constants of Ubbelohde viscometer in the range of 0 - 5 (K=0,001 - 100 mm²/s²) 
G2VI-1500  Calibration of Rotational Viscometer 
G2VI-9900  Special Calibration / Test 
(1) Measurements are carried out at 20°C, in case of any different temperature 1/4 of the calibration price will be added to the total price. 
(2) Determination of Viscometer constants of Ubbelohde viscometer in the range of 0 -– 2, 1/3 of the calibration price will be added to the total price. 
(3) In case of one more spindle use for calibration of rotational viscometer, 1/4 of the calibration price will be added to the total price for every spindle. 
(4) The price will be determined according to the request and the standards. 



VOLTAGE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1LV-0100  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Single Voltage Value (by Josephson Array Voltage Standard) 
G1LV-0101  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Two Voltage Values (by Josephson Array Voltage Standard) 
G1LV-0102  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Three Voltage Values (by Josephson Array Voltage Standard) 
G1LV-0110  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Single Voltage Value (by DC Voltage Standard Group) 
G1LV-0111  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Two Voltage Value (by DC Voltage Standard Group) 
G1LV-0112  DC Voltage Standard Calibration (1 V, 1.018 V, 10 V) Three Voltage Value (by DC Voltage Standard Group) 
G1LV-0120  Multifunction Transfer Standard 
G1LV-0200  Multifunction Calibrator Calibration (by Reference Standards) 
G1LV-0201  Multifunction Calibrator with External Amplifier Option (by Reference Standards) 
G1LV-0202  Multifunction Calibrator Calibration (by Reference Standards) (included adjustment procedure) 
G1LV-0203  Multifunction Calibrator with External Amplifier Option (by Reference Standards)(included adjustment procedure)   
G1LV-0204  Wideband Option Calibrator Calibration (by Reference Standards)  1, 6 
G1LV-0205  Multifunction Calibrator with Wideband and External Amplifier (by Reference Standards)  1, 6 
G1LV-0206  Wideband Option Calibrator Calibration (by Reference Standards)(included adjustment procedure)  1, 6 
G1LV-0207  Multifunction Calibrator with Wideband and External Amplifier Options (by Reference Standards) (included adjustment procedure)  1, 6 
G1LV-0209   
G1LV-0210  Multifunction Calibrator Calibration (by Working Standards) (DCV, ACV, DCI, ACI, R, C, T/C, P) 
G1LV-0211  Oscilloscope Option Calibrator Calibration (by Working Standards)  1, 6 
G1LV-0212  Multifunction Calibrator Calibration (by Working Standards) (DCV, ACV,DCI,ACI,R,C,T/C,P) (included adjustment procedure)  1, 6 
G1LV-0213  Oscilloscope Option Calibrator Calibration (by Working Standards)(included adjustment procedure)  1, 6 
G1LV-0214  Multifunction calibrator with Oscilloscope option (BW > 600 MHz)  1, 6 
G1LV-0215  Multifunction calibrator with Oscilloscope option (BW ? 300 MHz) (Adjustment included)  1, 6 
G1LV-0216  Multifunction calibrator with Oscilloscope option(300 MHz < BW ? 600 MHz) (Adjustment included)  1, 6 
G1LV-0217  Multifunction calibrator with Oscilloscope option (BW > 600 MHz) (Adjustment included)  1, 6 
G1LV-0220  DC Calibrator Calibration 
G1LV-0230  AC Calibrator Calibration 
G1LV-0240  Nanovoltmeter Calibration 
G1LV-0275  Multimeter Calibration (7 ½ digit) 
G1LV-0280  Multimeter Calibration (8 ½ digit by reference calibrator) 
G1LV-0281  Multimeter Calibration (8 ½ digit by reference calibrator) (included adjustment procedure) 
G1LV-0285  Multimeter Calibration (8 ½ digit by reference standards) 
G1LV-0286  Multimeter Calibration (8 ½ digit) (by reference standards) (included adjustment procedure) 
G1LV-0300  AC/DC Current Shunt Calibration (100 µA - 100 A, 10 Hz - 100 kHz)  1, 3 
G1LV-0301  Shunt Calibration (AC and DC) (Fluke Y5020)   
G1LV-0400  AC/DC Transfer Standard Calibration (10 Hz-1 MHz) Single Voltage Value  1, 4 
G1LV-0410  AC/DC Transfer Standard Calibration (10 Hz-1 MHz) Multiple Voltage Values  1, 4 
G1LV-0420  AC/DC Transfer Standard Calibration (1 MHz-100 MHz) Single Voltage Value  1, 5 
G1LV-0430  AC Measurement Standard Calibration 
G1LV-0431  AC Measurement Standard Calibration (included adjustment procedure) 
G1LV-0432  Wideband Option AC Measurement Standard Calibration (included adjustment procedure) 
G1LV-0433  Wideband Option AC Measurement Standard Calibration (included adjustment procedure) 
G1LV-0500  Oscilloscope Calibrator 
G1LV-0501  Oscilloscope Calibrator (included adjustment procedure) 
G1LV-0502  Oscilloscope Calibrator (9500B) 
G1LV-0503  Active Head 
G1LV-0515  Oscilloscope Calibration (600 MHz > BW< 6 GHz; Single Channel)   
G1LV-0516  Oscilloscope Calibration (600 MHz > BW < 6 GHz; Two Channels)   
G1LV-0517  Oscilloscope Calibration (600 MHz > BW < 6 GHz; Four Channels)   
G1LV-0620  Reference Voltage Divider Calibration 
G1LV-0630  Transconductance Amplifier Calibration (DCI < 20 A, ACI < 20 A) 
G1LV-0640  Transconductance Amplifier Calibration (DCI < 100 A, ACI < 100 A , 10 Hz - 100 kHz ) 
G1LV-9900  Special Calibration / Test 
(1) The service is in the acrreditation scope. 
(2) Price depends on the requirements. 
(3)  
(4)  
(5)  
(6)  



VOLUME DENSITY LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2HY-1100  Calibration of Piston Operated Pipette and Burette   
G2HY-1200  Calibration of volume vessels in the range of 0,1 mL - 5000 mL   
G2HY-1500  Calibration of metal volume vessels in the range of 2 L - 10 L  1, 2 
G2HY-1700  Calibration of metal volume vessels in the range of 20 L - 50 L  1, 2 
G2HY-1900  Calibration of metal volume vessels, 100 L  1, 2,4 
G2HY-2100  Calibration of metal volume vessels, 200 L  1, 2,4 
G2HY-2200  Calibration of metal volume vessels, 500 L  1, 2, 4 
G2HY-2300  Calibration of metal volume vessels, 1000 L  1, 2, 4 
G2HY-2400  Calibration of metal volume vessels, 2000 L  1, 2, 4 
G2HY-2500  Calibration of metal volume vessels, 5000 L  1, 2, 4 
G2HY-4100  Determination of reference liquid densities   
G2HY-4400  Calibration of hydrometers   
G2HY-4700  Calibration of digital density meter   
G2HY-9900  Special Calibration / Test 
(1) Calibration price is valid only for one scale. 25 % of the calibration price will be added to the total price for each additional scale. 
(2) In case of insufficient cleaning of your metal volume vessels, calibration service will not be available. 
(3) Price depends on the requirements. 
(4) The equipment must be delivered with the accessories necessary to discharge the calibration fluid (hoses, flanges, etc.). The customer is responsble for the transport and delivery of equipment to place of calibration and its removal. 



WATER & OTHER LIQUID FLOW LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G2AS-2100  Water Flowmeter Calibrations between 0,3 kg/h-15 kg/h  2,5,6,7 
G2AS-2300  0,01-6 m3/h Water Flowmeter Calibrations  1,2,5,6,7 
G2AS-2500  0.3-30 m3/h Water Flowmeter Calibrations  1,2,5,6,7 
G2AS-2700  Water Flowmeter Calibrations upto 100 m3/h  1,2,5,6,7 
G2AS-2900  Water Flowmeter Calibrations upto 250 m3/h  1,2,5,6,7 
G2AS-3100  Water Flowmeter Calibrations upto 1000 m3/h  1,2,5,6,7 
G2AS-3300  Water Flowmeter Calibrations upto 2000 m3/h  1,2,5,6,7 
G2AS-4000  Tests for Liquid Armatures  4,7 
G2AS-4800  Water Flow Meters Verification Tests (for 3 flowrates)  4,7 
G2AS-4900  On-Site Calibrations  3, 4, 8 
G2AS-5000  Tests Explained in Water Flowmeter Type Approval Regulations  4, 7 
G2AS-5200  Vane Test  4, 7 
G2AS-5600  Pump Tests  4, 7 
G2AS-9900  Specific Liquid Flow Calibration / Tests  4, 7 
(1) Acredited item. 
(2) Calibration price changes by %50 if more then one meter output calibration is requested, if it is decided that device sent for calibration is not working properly, %50 of the normal price is requested, and if the device is not clean enough for calibration, %50 of the price will also be requsted for cleaning purposes from the customer. 
(3) On-Site calibration price is twice the price of calibration at UME and it may increase if there is any other needs for calibration on-site. Travelling expenses will be added to the price. 
(4) Price may change according to device type and test 
(5) Price increases by %50 for the requests of calibrations at temperatures other than standard laboratory conditions 
(6) Price increases by %50 for flow meter adjustment (i.e. K factor or similar) requests 
(7) In case of contamination of the flow measurement systems, lines and water due to the equipment sent to the calibration as dirty, the total cost of the water to be renovated, the work force spent on cleaning and the consumables used for cleaning are also taken from the customer. 
() Price increases by %50 for requests of calibrations of meters heavier than 40 kg (for 0-100 m3/h range) and heavier than 100 kg (for 100-2000 m3/h range). 



3-DIMENSION MEASUREMENTS (CO-ORDINATE METROLOGY) CALIBRATION / TEST LIST

CODE NAME NOTE
G2BU-0100  Cylindrical Square (Roundness, Squareness, Straightness and Parallelism Measurements) 
G2BU-0110  Granite or Steel Square (Squareness Standard)  1,2 
G2BU-0200  Height Gauge 
G2BU-0210  Check Gauge (Calliper Checker)  1,3 
G2BU-0220  Riser Block 
G2BU-0400  Tapered Ring-Plug Gauges (calibration with CMM) 
G2BU-0410  Tapered Thread Ring-Plug Gauge (calibration with CMM) 
G2BU-0500  Plain Go-NoGo Ring-Plug Gauge (calibration with CMM) (for at least 10 pieces) 
G2BU-0510  Parallel Thread Go-NoGo Ring-Plug Gauge (calibration with CMM) (for at least 10 pieces) 
G2BU-0520  Snap Gauge Calibration (calibration with CMM) (for at least 10 pieces) 
G2BU-2100  Pin Gauge (Gauges for Aircraft Engines) 
G2BU-9900  Special Calibration / Test 
(1) Acredited Item. 
(2) Prices differ acc. to workpiece dimensions and number of measurement points. 
(3) The price of the check gauges longer than 600mm are re-evaluated 
(4) Price is calculated with the formula (2330+n*165) where n: Number of pins 



CALIBRATION / TEST LIST

CODE NAME NOTE
G1TF-1000  Measurement of Thermal Conductivity by Guarded Hot Plate Method, 0,0015 W/m.K - 0,35 W/m.K (From 25 °C to 250 °C)  1,2,3,4 
G1TF-2000  Measurement of Thermal Conductivity by Heat Flow Method, 0.004 W/m.K - 2 W/m.K (From -20 °C to 90 °C)  1,2,3,4 
G1TF-3000  Measurement of Thermal Values by Differential Scanning Calorimetry (From -180 °C to 700 °C)  1,2,3,4 
G1TF-4000  Thermal Camera Radiometric Calibration (-50°C / 800 °C)  2,3,5,6 
G1TF-4100  Thermal Camera Radiometric Calibration (800°C / 1600 °C)  2,3,5,6 
G1TF-4200  Thermal Camera Radiometric Calibration (1600°C / 2300 °C)  2,3,5,6 
G1TF-4300  Thermal Camera Uniformity Measurement (-20°C / 50°C) (at 3 measurement points)  1,2,3,6 
G1TF-4400  Thermal Camera Uniformity Measurement (50°C / 100°C) (at 3 measurement points)  1,2,3,6 
G1TF-5000  IR Calibrators / Blackbody Surface Temperature Measurement  1,2,3,7 
G1TF-6000  IR Calibrators / Blackbody Emissivity Measurement  1,2,3,8 
G1TF-9900  Special Calibration / Test  1,2,3,9 
(1)  
(2)  
(3)  
(4)  
(5)  
(6)  
(7)  
(8)  
(9)  



CALIBRATION / TEST LIST

CODE NAME NOTE
G1MM-1100  Calibration of Patient Simulator   
G1MM-1110     
G1MM-1200  Calibration of NIBP Simulator   
G1MM-1210     
G1MM-1220     
G1MM-1300  Calibration of SpO2 Test Device   
G1MM-1320  Filter Media for Respirators   
G1MM-2100  Calibration of Electrical Safety Analyzer   
G1MM-3100  Calibration of Electro-surgery Analyzer   
G1MM-3200  Calibration of Defibrilator Calibrator   
G1MM-4100  Calibration of Gas Flow Analyzer   
G1MM-4200     
G1MM-4300     
G1MM-4400     
G1MM-5100  Calibration of Infusion Pump Analyzer   
G1MM-6100  Ultrasonic Power Calibration   
G1MM-7100  Hearing Aid Acoustic Tests   
G1MM-8100     
G1MM-8200     
G1MM-8300     
G1MM-8400     
G1MM-8500     
G1MM-9800  Special Ultrasound/Underwater Acoustical Measurements 
G1MM-9900  Special Calibration / Test 