CODE |
NAME |
NOTE |
G1FV-0100 |
Visual Inspection Experiment |
1, 2, 3, 4, 10, 12 |
G1FV-0200 |
Maximum Power Experiment |
2, 3, 4, 5, 6 |
G1FV-0250 |
|
2, 3, 4, 5, 6 |
G1FV-0300 |
Insulation Resistance Experiment |
3, 4 |
G1FV-0400 |
Temperature Coefficient Experiment |
3, 4, 6, 7, 12 |
G1FV-0500 |
Nominal Module Operating Temperature (NMOT) Experiment |
3, 4 |
G1FV-0600 |
Performance Test of Module at STC and NMOT Conditions |
3, 4, 5, 6, 12 |
G1FV-0700 |
Low Irradiance Performance Experimet |
3, 4, 5, 6, 12 |
G1FV-0800 |
Outdoor Exposure Experiment |
3, 4 |
G1FV-0900 |
Hot-Spot Endurance Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-1000 |
UV Preconditioning Experiment (15 kWh) |
1, 2, 3, 4, 5, 6, 12 |
G1FV-1100 |
Thermal Cycling Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-1200 |
Humidity Freeze Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-1300 |
Damp Heat Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-1400 |
Robustness of Terminations Experiments |
1, 2, 3, 4, 5, 6 |
G1FV-1500 |
Wet Leakage Current Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-1600 |
Mechanical Load Experiment |
1, 2, 3, 4, 5, 6, 12 |
G1FV-1650 |
|
1, 2, 3, 4, 5, 6, 12 |
G1FV-1700 |
Hail Experiment |
1, 2, 3, 4, 5, 6, 12 |
G1FV-1800 |
Bypass Diode Thermal |
1, 2, 3, 4, 5, 6 |
G1FV-1850 |
Bypass Diode Functionality Experiment |
1, 2, 3, 4, 5, 6, 12 |
G1FV-1900 |
Stabilisation Experiment |
1, 2, 3, 4, 5, 6, 12 |
G1FV-2000 |
Accessibility Experiment |
1, 2, 3, 4, 5, 6 |
G1FV-2100 |
Cut Susceptibility Experiment |
1, 2, 4 |
G1FV-2200 |
Ground Continuity Experiment |
1, 2, 4 |
G1FV-2300 |
Impulse Voltage Experiment |
1, ,2, 4 |
G1FV-2400 |
Tempereture Experiment |
11 |
G1FV-2500 |
Fire Experiment |
11 |
G1FV-2600 |
Reverse Current Overload Experiment |
1, ,2, 4 |
G1FV-2700 |
Module Breakage Deneyi |
1, ,2, 4 |
G1FV-2800 |
Materials Creep Experiment |
11 |
G1FV-2900 |
UV Experiment |
1, ,2, 4 |
G1FV-3000 |
Cold Conditioning Experiment |
11 |
G1FV-3100 |
Dry Heat Conditioning Experiment |
11 |
G1FV-3200 |
Spectral Responsivity Experiment |
1, 2, 3, 5, 6, 12 |
G1FV-3300 |
Light Induced Degradation (LID) Experiment |
11 |
G1FV-3400 |
Potantial Induced Degradation (PID) Experiment |
8, 11 |
G1FV-3500 |
Energy Rating Experiment |
9, 11 |
G1FV-3600 |
Reference Cell Calibration |
2, 3, 5 |
G1FV-3700 |
Simulator Classifications
|
5, 7 |
G1FV-9900 |
Special Calibration / Test |
11 |
(1) |
The experiment is performed according to IEC 61215-2 standard. |
(2) |
The experiment is performed according to IEC 61730-2 standard. |
(3) |
The experiment is performed according to IEC 61730-2 standard. |
(4) |
The experiment is performed according to IEC 61853-1 standard. |
(5) |
The experiment is performed according to IEC TS 61853-2, Method A standard. |
(6) |
The price will be evaluated with respect to the experiments sequence given in the standard |
(7) |
The experiment is performed according to IEC TS 62804-1, Method A standard. |
(8) |
|
(9) |
|
(10) |
|
(11) |
|
(12) |
|
CODE |
NAME |
NOTE |
G1RA-4100 |
UVA Irradiance Meter |
1 |
G1RA-4120 |
Total UVB Irradiance Responsivity (280 nm - 315 nm) |
2 |
G1RA-4130 |
Total UVC Irradiance Meter (200 nm - 280 nm) |
|
G1RA-4150 |
Spectral Irradiance Responsivity ( 280 nm-1100 nm) |
|
G1RA-4200 |
Spectral Irradiance of Sources, (W/m2 ), (250 nm-2500 nm) |
|
G1RA-4300 |
Solar Irradiance Meter (200nm-1100nm) |
|
G1RA-4400 |
Pyranometer |
3 |
G1RA-4600 |
Pyrheliometer |
3 |
G1RA-4700 |
Spectral Radiance Responsivity |
|
G1RA-4800 |
Spectral Radiance |
|
G1RA-6400 |
Pulsed Laser Energy (1064 nm, <= 150 mJ) |
4 |
G1RA-6500 |
Laser Power Meter |
5 |
G1RA-6700 |
Spectral Responsivity (380 nm-1100 nm) |
|
G1RA-6800 |
Spectral Responsivity (1100 nm-1650 nm) |
|
G1RA-6900 |
Spectral Responsivity (250 nm-380 nm) |
|
G1RA-9900 |
Special Calibration / Test |
5 |
(1) |
Calibration of a UVA detector is carried out under Spectroline SB-100P/F model irradiance lamp supported with a UV filter (Spectronics Corporation, model 2F958). Typical calibration points are 100 uW/cm^2, 500 uW/cm^2, 1000 uW/cm^2, 2000 uW/cm^2 and 3000 uW/cm^2. |
(2) |
Calibration of a UVB radiometer is carried out under a deuterium light sources. |
(3) |
Measurements are carried out at provided environmental conditions (June - September) |
(4) |
The calibration is performed at 355 nm, 532 nm and 1064 nm pulse wavelengths and at an energy range of 10 mJ to 200 mJ. The calibration fee is valid for only one wavelength. |
(5) |
The calibration is performed at 488 nm, 515 nm, 532 nm, 633 nm and 1064 nm laser (CW) wavelengths and at optical power range of 10 mW to 1000 mW. The price is valid only for measurements of two wavelengths. |
(6) |
The price will be determined according to technical requirements. |
CODE |
NAME |
NOTE |
G1SP-1100 |
Luminous Flux (Tungsten Lamps, 2856 K), (5 lm-5000 lm) |
|
G1SP-1150 |
Spectral Luminous Flux ( LED and SSL Lamps with max. 10 cm size), (0,7 lm-30000 lm) |
|
G1SP-1500 |
Luminous Intensity (1 cd-10000 cd) |
1 |
G1SP-1550 |
Spatial Luminous Intensity ( Tungsten, LED and SSL Lamps with 2 cm size) |
8 |
G1SP-2100 |
Color Coordinates of Light Sources, (CIE-xy, CIE-u'v') |
|
G1SP-2300 |
Color Temperature of Light Sources (2856 K) |
2 |
G1SP-2500 |
Color Plate (CIEXYZ, CIExy, CIELAB, DeLtaE), 0°:45° |
3 |
G1SP-2700 |
Color Plate (CIEXYZ, CIExy, CIELAB, DeltaE), d:0° and d:8° |
3 |
G1SP-2900 |
Colorimeter (DeltaE), 0°:45° and d:8° |
3 |
G1SP-3100 |
Luminance Responsivity (Luminance Meter), (1 cd/m2-1000 cd/m2) |
4 |
G1SP-3300 |
Luminance Source (27 cd/m2-5000 cd/m2) |
|
G1SP-3500 |
Illuminance (Luxmeter), (0,1 lx - 5000 lx) |
5 |
G1SP-3600 |
Luminous Responsivity (Photometer Head), (0,0002 nA/lx - 10 mA/lx) |
|
G1SP-5000 |
Spectral Regular Reflectance |
6 |
G1SP-5300 |
Gloss (Gloss/ Gloss Plate) |
7 |
G1SP-5500 |
Spectral Diffuse Reflectance |
6 |
G1SP-6000 |
Absolute Diffuse Reflectance (250 nm-2500 nm) |
8 |
G1SP-7000 |
Spectrophotometer (UV/VIS) |
|
G1SP-7100 |
Spectral Regular Transmittance |
6 |
G1SP-7300 |
Total Transmittance |
6 |
G1SP-7400 |
Wavelength Measurements of Light Sources |
|
G1SP-7500 |
Diffuse Transmittance Meter (Densitometer) |
6 |
G1SP-7600 |
Diffuse Transmittance (Step Density Strip / Film) |
6 |
G1SP-9900 |
Special Calibration / Test |
8 |
(1) |
The price given is valid for single solid angle and single ray direction. |
(2) |
Calibration is performed only at 2856 K color temperature. |
(3) |
Only valid for one type of lightning condition |
(3) |
Only valid for one type of lightning condition |
(4) |
The illuminance measurements are carried out at 50 lx, 500 lx , 800 lx and 2000 lx levels. If the customer request measurements at different points, it must be stated during the application. The extra measurement points between 0,1 lx and 4000 lx are subjected to a separate pricing per each additional measurement point. |
(5) |
The price is valid for one of the two wavelength ranges listed below and applies to a single bandwidth (SBW).
1) 250 nm - 1100 nm
2) 1100 nm - 2500 nm
Two separate demands are required for neutral density filters and wavelength accuracy filters located in the same box.
|
(6) |
The price is valid for the angles of 20°, 60°, and 85° |
(7) |
The price will be determined according to the measurement conditions and customer request. |
(8) |
|
(9) |
|