CODE |
NAME |
NOTE |
G1ER-0100 |
It is called "electrical bursts (electrical fast transients)" in type tests.
|
1, 2, 19, 21 |
G1ER-0200 |
Conducted Emission (Use of Absorbing Clamp) |
1, 2, 19, 21 |
G1ER-0300 |
Conducted Emission (Use of DIA) |
1, 2, 19, 21 |
G1ER-0400 |
Conducted Emission (Use of Current Probe) |
1, 2, 19, 21 |
G1ER-0500 |
Conducted Emission (Use of Voltage Probe) |
1, 2, 19, 21 |
G1ER-0600 |
Conducted Emission (Harmonics) |
1, 2, 19, 21 |
G1ER-0700 |
Conducted Emission (Flicker) |
1, 2, 19, 21 |
G1ER-0800 |
Radiated Emission |
1, 2, 19, 21 |
G1ER-0900 |
Conducted Immunity (Use of CDN) |
1, 2, 19, 21 |
G1ER-0950 |
Conducted Immunity (Use of BCI) |
1, 2, 19, 21 |
G1ER-1000 |
Conducted Immunity (ESD) |
1, 4, 14, 19, 21 |
G1ER-1100 |
Conducted Immunity (EFT) |
1, 2, 15, 19, 21 |
G1ER-1200 |
Conducted Immunity (Surge) |
1, 2, 18, 19, 21 |
G1ER-1300 |
Conducted Immunity (Voltage Dips and Interruptions) |
1, 2, 16, 19, 21 |
G1ER-1350 |
Magnetic Immunity (50 / 60 Hz) |
1, 2, 19, 21 |
G1ER-1400 |
Radiated Immunity (3 V/m - 30 V/m, 26 MHz - 6.5 GHz) |
1, 3, 17, 19, 21 |
G1ER-3230 |
Full EMC Tests of Vehicles and Tractors According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive |
1, 3, 19, 21 |
G1ER-3330 |
EMC Tests of Vehicle/Tractor Sub-Assemblies According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive
|
1, 3, 19, 21 |
G1ER-3600 |
RE101, Magnetic Field, 30 Hz - 100 kHz |
1, 2, 4, 19, 21 |
G1ER-3700 |
RE102, Electric Field (10 kHz –- 18 GHz) |
1, 3, 4, 19, 21 |
G1ER-3900 |
CE101, Power Leads, 30 Hz - 10 kHz (single phase) |
1, 2, 19, 21 |
G1ER-4000 |
CE102, Power Leads, 10 kHz - 10 MHz (single phase) |
1, 2, 19, 21 |
G1ER-4200 |
RS101, Magnetic Field, 30 Hz - 100 kHz |
1, 2, 4, 6, 11,19, 21 |
G1ER-4300 |
RS103, Electric Field, 2 MHz - 18 GHz, 10 V/m - 200 V/m, EUT Surface up to 900 cm²
|
1, 3, 5, 6, 7, 10, 19, 21 |
G1ER-4400 |
CS101, Power Leads, 30 Hz - 150 kHz (single phase) |
1, 2, 6, 11, 19, 21 |
G1ER-4710 |
CS106 Power Leads, (single phase) |
1, 2, 11, 19, 21 |
G1ER-4900 |
CS114, Bulk Cable Injection, 10 kHz - 200 MHz |
1, 2, 6, 11, 19, 21 |
G1ER-5000 |
CS115, Bulk Cable Injection/Impulse Excitation |
1, 2, 11, 19, 21 |
G1ER-5100 |
CS116, Damped Sinusoidal Transients |
1, 2, 11, 19, 21 |
G1ER-5110 |
CS118, Electrostatic Discharge |
1, 4, 19, 21 |
G1ER-5210 |
Active-Passive Rod and Loop Antenna Calibration (Frequency range: 5 Hz - 30 MHz) |
8, 12, 20 |
G1ER-5220 |
Biconical, Bilog, Log-Periodic, Horn Antenna Calibration (Frequency range: 30 MHz - 300 MHz or 200 MHz - 1 GHz) |
8, 12, 13, 20 |
G1ER-5225 |
Bilog / Mini Biconical Antenna Calibration (Frequency range: 30 MHz - 1 GHz)
|
8, 12, 13, 20 |
G1ER-5230 |
Horn Antenna Calibration (Frequency range: 1 GHz - 18 GHz) |
8, 12, 13, 20 |
G1ER-5240 |
Horn Antenna Calibration (Frequency range: 18 GHz - 26,5 GHz) |
8, 12, 13, 20 |
G1ER-5250 |
Horn Antenna Calibration (Frequency range: 26 GHz - 40 GHz) |
8,12,13,20 |
G1ER-5310 |
Electric/Magnetic Field Probe Calibration ( Frequency range: 30 Hz - 32 kHz) |
8, 12, 20 |
G1ER-5320 |
Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 MHz) |
8, 12, 20 |
G1ER-5330 |
Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 30 MHz) |
8, 12, 20 |
G1ER-5340 |
Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 GHz) |
8, 12, 20 |
G1ER-5350 |
Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 20 GHz) |
8, 12, 20 |
G1ER-5360 |
Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 40 GHz) |
8, 12, 20 |
G1ER-6100 |
Daily Use of Semi Anechoic Chamber (Radiated Immunity / 8 Hours) |
22 |
G1ER-6200 |
Daily Use of Semi Anechoic Chamber (Radiated Emission / 8 Hours) |
22 |
G1ER-6300 |
Daily Use of Screened Room (Conducted Emission-Immunity / 8 Hours) |
22 |
G1ER-6400 |
Absorbing Clamp Calibration |
8, 20 |
G1ER-6510 |
Voltage/Current Probe Calibration (Frequency range for voltage probes: 150 kHz - 30 MHz, Frequency range for current probes: 30 Hz - 500 MHz, measuring range (-30 dBs) - (70 dBs)) |
8, 20 |
G1ER-9900 |
Special Calibration / Test |
9 |
(1) |
Accredited Service
|
(2) |
30% of the test fee will be added to the total test fee for each additional operating mode and/or each additional port/phase.
|
(3) |
50% of the test fee will be added to the total test fee for each additional operating mode.
|
(4) |
10% of the test fee will be added to the total test fee for each additional application point.
|
(5) |
30% of the test fee will be added to the total test fee for each additional 900 cm2 area of the EUT surface.
|
(6) |
The stated fee is valid for a dwell time up of 6 s maximum. %50 of the test fee will be added to the total test fee for each additional time period of 6 s.
|
(7) |
50% of the test fee will be added to the total test fee for the frequency range of 18 GHz –- 40 GHz.
|
(8) |
50% of the calibration fee will be charged if the equipment under calibration is found to be defective.
|
(9) |
The test/calibration fee is determined in accordance with the tests/calibrations to be performed.
|
(10) |
If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Semi Anechoic Chamber (Radiated Immunity)
|
(11) |
If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Screened Room (Conducted Emission-Immunity)
|
(12) |
The calibration frequency range is determined as per manufacturer specifications.
|
(13) |
Horn antenna measurements will be performed in the vertical polarization. The other antenna measurements will be performed in the horizontal polarization.
|
(14) |
It is called "electrostatic discharges" in type tests.
|
(15) |
It is called "electrical bursts (electrical fast transients)" in type tests.
|
(16) |
It is called "voltage variations, short time power reductions, voltage dips and short interruptions" in type tests.
|
(17) |
It is called "radiated immunity or immunity to radiated electromagnetic fields" in type tests.
|
(18) |
It is called "surges" in type tests.
|
(19) |
If you accept our offer, 15% of the total test fee must be paid in advance within 5 business days in order to reserve the specified dates for you. In order to provide the requested service, the remaining balance must be deposited in advance and the payment receipt must be sent to our institute at least 5 days before the service date. For tests cancelled up to 30 days before the service date, 15% of the previously paid amount will not be refunded and it will be invoiced and the remaining balance will be returned to you, if any. If the requested services are not cancelled in writing until 30 days in advance, 25% of the total test fee will be invoiced. If the customer does not come for testing on the specified date and postpone the tests, the daily room usage fee for radiated emission tests in our Industrial Services Catalogue will apply.
|
(20) |
The calibration fee is valid for TÜBİTAK UME's standard calibration frequencies. Additional measurement frequencies, if requested, may be charged separately.
|
(21) |
|