ELECTROMAGNETIC METROLOGY LABORATORY CALIBRATION / TEST LIST

ELECTROMAGNETIC RADIATION LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1ER-0100  It is called "electrical bursts (electrical fast transients)" in type tests.   1, 2, 19, 21 
G1ER-0200  Conducted Emission (Use of Absorbing Clamp)  1, 2, 19, 21 
G1ER-0300  Conducted Emission (Use of DIA)  1, 2, 19, 21 
G1ER-0400  Conducted Emission (Use of Current Probe)  1, 2, 19, 21 
G1ER-0500  Conducted Emission (Use of Voltage Probe)  1, 2, 19, 21 
G1ER-0600  Conducted Emission (Harmonics)  1, 2, 19, 21 
G1ER-0700  Conducted Emission (Flicker)  1, 2, 19, 21 
G1ER-0800  Radiated Emission  1, 2, 19, 21 
G1ER-0900  Conducted Immunity (Use of CDN)  1, 2, 19, 21 
G1ER-0950  Conducted Immunity (Use of BCI)  1, 2, 19, 21 
G1ER-1000  Conducted Immunity (ESD)  1, 4, 14, 19, 21 
G1ER-1100  Conducted Immunity (EFT)  1, 2, 15, 19, 21 
G1ER-1200  Conducted Immunity (Surge)  1, 2, 18, 19, 21 
G1ER-1300  Conducted Immunity (Voltage Dips and Interruptions)  1, 2, 16, 19, 21 
G1ER-1350  Magnetic Immunity (50 / 60 Hz)  1, 2, 19, 21 
G1ER-1400  Radiated Immunity (3 V/m - 30 V/m, 26 MHz - 6.5 GHz)  1, 3, 17, 19, 21 
G1ER-3230  Full EMC Tests of Vehicles and Tractors According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive  1, 3, 19, 21 
G1ER-3330  EMC Tests of Vehicle/Tractor Sub-Assemblies According To 72/245, 75/322, 95/54 or E.C.E. 10 Directive   1, 3, 19, 21 
G1ER-3600  RE101, Magnetic Field, 30 Hz - 100 kHz  1, 2, 4, 19, 21 
G1ER-3700  RE102, Electric Field (10 kHz –- 18 GHz)  1, 3, 4, 19, 21 
G1ER-3900  CE101, Power Leads, 30 Hz - 10 kHz (single phase)  1, 2, 19, 21 
G1ER-4000  CE102, Power Leads, 10 kHz - 10 MHz (single phase)  1, 2, 19, 21 
G1ER-4200  RS101, Magnetic Field, 30 Hz - 100 kHz  1, 2, 4, 6, 11,19, 21 
G1ER-4300  RS103, Electric Field, 2 MHz - 18 GHz, 10 V/m - 200 V/m, EUT Surface up to 900 cm²   1, 3, 5, 6, 7, 10, 19, 21 
G1ER-4400  CS101, Power Leads, 30 Hz - 150 kHz (single phase)  1, 2, 6, 11, 19, 21 
G1ER-4710  CS106 Power Leads, (single phase)  1, 2, 11, 19, 21 
G1ER-4900  CS114, Bulk Cable Injection, 10 kHz - 200 MHz  1, 2, 6, 11, 19, 21 
G1ER-5000  CS115, Bulk Cable Injection/Impulse Excitation  1, 2, 11, 19, 21 
G1ER-5100  CS116, Damped Sinusoidal Transients  1, 2, 11, 19, 21 
G1ER-5110  CS118, Electrostatic Discharge  1, 4, 19, 21 
G1ER-5210  Active-Passive Rod and Loop Antenna Calibration (Frequency range: 5 Hz - 30 MHz)  8, 12, 20 
G1ER-5220  Biconical, Bilog, Log-Periodic, Horn Antenna Calibration (Frequency range: 30 MHz - 300 MHz or 200 MHz - 1 GHz)  8, 12, 13, 20 
G1ER-5225  Bilog / Mini Biconical Antenna Calibration (Frequency range: 30 MHz - 1 GHz)   8, 12, 13, 20 
G1ER-5230  Horn Antenna Calibration (Frequency range: 1 GHz - 18 GHz)  8, 12, 13, 20 
G1ER-5240  Horn Antenna Calibration (Frequency range: 18 GHz - 26,5 GHz)  8, 12, 13, 20 
G1ER-5250  Horn Antenna Calibration (Frequency range: 26 GHz - 40 GHz)  8,12,13,20 
G1ER-5310  Electric/Magnetic Field Probe Calibration ( Frequency range: 30 Hz - 32 kHz)  8, 12, 20 
G1ER-5320  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 MHz)  8, 12, 20 
G1ER-5330  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 30 MHz)  8, 12, 20 
G1ER-5340  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 3 GHz)  8, 12, 20 
G1ER-5350  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 20 GHz)  8, 12, 20 
G1ER-5360  Electric/Magnetic Field Probe Calibration( Frequency range: 30 Hz - 40 GHz)  8, 12, 20 
G1ER-6100  Daily Use of Semi Anechoic Chamber (Radiated Immunity / 8 Hours)  22 
G1ER-6200  Daily Use of Semi Anechoic Chamber (Radiated Emission / 8 Hours)  22 
G1ER-6300  Daily Use of Screened Room (Conducted Emission-Immunity / 8 Hours)  22 
G1ER-6400  Absorbing Clamp Calibration  8, 20 
G1ER-6510  Voltage/Current Probe Calibration (Frequency range for voltage probes: 150 kHz - 30 MHz, Frequency range for current probes: 30 Hz - 500 MHz, measuring range (-30 dBs) - (70 dBs))  8, 20 
G1ER-9900  Special Calibration / Test 
(1) Accredited Service  
(2) 30% of the test fee will be added to the total test fee for each additional operating mode and/or each additional port/phase.  
(3) 50% of the test fee will be added to the total test fee for each additional operating mode.  
(4) 10% of the test fee will be added to the total test fee for each additional application point.  
(5) 30% of the test fee will be added to the total test fee for each additional 900 cm2 area of the EUT surface.  
(6) The stated fee is valid for a dwell time up of 6 s maximum. %50 of the test fee will be added to the total test fee for each additional time period of 6 s.  
(7) 50% of the test fee will be added to the total test fee for the frequency range of 18 GHz –- 40 GHz.  
(8) 50% of the calibration fee will be charged if the equipment under calibration is found to be defective.  
(9) The test/calibration fee is determined in accordance with the tests/calibrations to be performed.  
(10) If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Semi Anechoic Chamber (Radiated Immunity)  
(11) If determination of a threshold value is requested, it will be charged extra in the scope of Daily Use of Screened Room (Conducted Emission-Immunity)  
(12) The calibration frequency range is determined as per manufacturer specifications.  
(13) Horn antenna measurements will be performed in the vertical polarization. The other antenna measurements will be performed in the horizontal polarization.  
(14) It is called "electrostatic discharges" in type tests.  
(15) It is called "electrical bursts (electrical fast transients)" in type tests.  
(16) It is called "voltage variations, short time power reductions, voltage dips and short interruptions" in type tests.  
(17) It is called "radiated immunity or immunity to radiated electromagnetic fields" in type tests.  
(18) It is called "surges" in type tests.  
(19) If you accept our offer, 15% of the total test fee must be paid in advance within 5 business days in order to reserve the specified dates for you. In order to provide the requested service, the remaining balance must be deposited in advance and the payment receipt must be sent to our institute at least 5 days before the service date. For tests cancelled up to 30 days before the service date, 15% of the previously paid amount will not be refunded and it will be invoiced and the remaining balance will be returned to you, if any. If the requested services are not cancelled in writing until 30 days in advance, 25% of the total test fee will be invoiced. If the customer does not come for testing on the specified date and postpone the tests, the daily room usage fee for radiated emission tests in our Industrial Services Catalogue will apply.  
(20) The calibration fee is valid for TÜBİTAK UME's standard calibration frequencies. Additional measurement frequencies, if requested, may be charged separately.  