HIGH VOLTAGE LABORATORY CALIBRATION / TEST LIST

HIGH VOLTAGE LABORATORY CALIBRATION / TEST LIST

CODE NAME NOTE
G1YG-1050  DC High Voltage Measuring System Calibration (100 kV - 400 kV)  1, 2, 3, 7,11 
G1YG-1250  DC High Voltage Measuring System/Probe Calibration (1 kV - 100 kV)  1, 2, 3, 7, 11 
G1YG-2050  AC High Voltage Measuring System Calibration (45 Hz-60 Hz, 101 kV - 400 kV)  1, 2, 3, 9, 11 
G1YG-2555  Calibration of High Frequency High Voltage Measuring System (50 Hz-300 Hz, 1 kV-200 kV)  2, 3, 9, 11 
G1YG-2655  Calibration of VLF (Very Low Frequency) AC High Voltage Device (1 kV-120 kV)  2, 3, 9, 11 
G1YG-2800  Calibration of AC High Voltage Measuring System (45 Hz-60 Hz, 1 kV - 100 kV)  1, 2, 3, 9 
G1YG-3050  Lightning Impulse High Voltage Measuring System Calibration (40kV - 1000kV)  1, 2, 3, 11 
G1YG-3100  Switching Impulse High Voltage Measuring System Calibration (40kV - 850kV)  1, 2, 3, 11 
G1YG-3200  Impulse High Voltage Measuring System/Probe Calibration (<40 kV)  1, 2, 3, 11 
G1YG-3250  Impulse High Voltage Source Calibration (1 kV - 40 kV) (Includes volatge and current option)  1, 2, 3, 11 
G1YG-3260  Calibration of Impulse High Current Shunt/Probe  2, 3, 11 
G1YG-4400  PD Detector Calibration (>2 pC)  1, 2, 3, 11 
G1YG-4450  PD Calibrator Calibration  1, 2, 3, 11 
G1YG-4451  Surge Device Calibration  2, 3, 11 
G1YG-4452  Electrostatic Field Meter Calibration  2, 3, 11 
G1YG-5060  Calibration of Capacitance and Dissipation Factor Measuring Device  1, 2, 3, 4, 11 
G1YG-5070  Calibration of Standard Capacitor  1, 2, 3, 4, 11 
G1YG-6000  Calibration of Oil Tester  1, 2, 3, 11 
G1YG-6025  Insulation Tester Calibration (up to 10 kV, Meger etc.)  1, 2, 3, 7, 8, 11 
G1YG-6050  Calibration of High Voltage Field Meter  1, 2, 3, 11 
G1YG-9900  Special High Voltage Test/Measurements  2, 3, 5, 6, 10 
(1) All our activities are peformed according to IEC 60060-2 standard. 
(2) The calibrations have been priced for five measuring points at least. For the each additional measuring point, 10% of extra charge will be added to the calibration fee. 
(3) Customer is responsible to supply the uninterrupted source for on-site calibration according to the IEC 60060-1 and IEC 60060-2. No any repay in the case of problem about breakdown, out of system etc. 
(4) C/tand measurement and calibrations performed in the TÜBİTAK UME High Voltage Laboratory under (50 Hz) AC high voltage and up to 400 kV. On site C/tand measurement and calibrations performed maximum up to 10kV.. 
(5) Opening hours are 08:00 to 12:00 and 13:00 to 16:30. 
(6) Pricing is based on demand. 
(7) Calibration cost for one polarty.For double polarty %50 calibration cost is added. 
(8)  
(9) Our accreditation scope can be reached from TÜRKAK web site (www.turkak.org.tr). 
(10)  
(11)